Schwachstellen werden geladen…
Schwachstellen werden geladen…
CVE-2002-20001
The Diffie-Hellman Key Agreement Protocol allows remote attackers (from the client side) to send arbitrary numbers that are actually not public keys, and trigger expensive server-side DHE modular-exponentiation calculations, aka a D(HE)at or D(HE)ater attack. The client needs very little CPU resources and network bandwidth. The attack may be more disruptive in cases where a client can require a server to select its largest supported key size. The basic attack scenario is that the client must claim that it can only communicate with DHE, and the server must be configured to allow DHE.
Dieser Datensatz: Live-Anbindung— zuletzt abgerufen: 7. November 2026 um 02:35.
Hersteller
Veröffentlicht
11. November 2021
Zuletzt geändert
23. September 2026
Direkt aus NVD, CISA oder vom Hersteller übernommen — teils auf Englisch, unverändert gegenüber der Quelle.
The Diffie-Hellman Key Agreement Protocol allows remote attackers (from the client side) to send arbitrary numbers that are actually not public keys, and trigger expensive server-side DHE modular-exponentiation calculations, aka a D(HE)at or D(HE)ater attack. The client needs very little CPU resources and network bandwidth. The attack may be more disruptive in cases where a client can require a server to select its largest supported key size. The basic attack scenario is that the client must claim that it can only communicate with DHE, and the server must be configured to allow DHE.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Attack Vector
NETWORK
Privileges Required
NONE
User Interaction
NONE
Vertraulichkeit
Keine
Integrität
Keine
Verfügbarkeit
Hoch
Ausnutzungswahrscheinlichkeit innerhalb von 30 Tagen
24.6%
Perzentil
98e
Quelle: FIRST.org, aktualisiert am 6. November 2026.
External protective measures are required: Disable the webserver after configuration, if possible, by following these steps: - Enable SSH via the web server. - Login to the SSH server. - Disable the webserver via SSH portal. - Reboot the device. or: - Use HTTPS rather than HTTP while using the webserver. - Minimize network exposure for affected products and ensure that they are not accessible via the Internet. - Isolate affected products from the corporate network. - If remote access is required, use secure methods such as virtual private networks(VPNs). Pepperl+Fuchs will provide an update to address some of these vulnerabilities in the future.
Unsere eigene Einordnung und unser Kontext zu den obigen Quelldaten.
IACS-Radar-Einordnung
Unsere eigene Einordnung und unser Kontext zu dieser Schwachstelle — keine offizielle Quelle.
IACS-Radar-Prioritätswert
Basierend auf CVSS 7.5, EPSS 24.6%, industrielle Relevanz 40/100.
Kombiniert CVSS, EPSS, KEV-Status, industrielle Relevanz und Expositionsrelevanz — eine Ergänzung, kein Ersatz für die einzelnen Werte darunter und darüber.
Voraussetzungen für eine Ausnutzung
Operative Auswirkungen & Energierelevanz
Möglicher Verlust der Sicht auf oder der Kontrolle über den Prozess bei erfolgreicher Ausnutzung.
Keine starken energiesektorspezifischen Signale erkannt; allgemeine OT-/ICS-Relevanz.
Empfohlene defensive Maßnahmen
Industrieller Relevanzwert
Die Einstufung ist vorläufig; eine manuelle Überprüfung durch einen OT-Security-Analysten wird empfohlen.
Klassifiziert von IACS Radar-analysepijplijn (geautomatiseerd) am 7. November 2026.
IEC-62443-Zuordnung
Automatische IACS-Radar-Einordnung anhand der gemeldeten CWE-Schwächeklassifizierung; keine offizielle Zertifizierungsaussage.