Endress+Hauser Ecograph T (Neutral/Private Label) (RSG35, ORSG35) and Memograph M (Neutral/Private Label) (RSG45, ORSG45) with Firmware version V2.0.0 and above is prone to exposure of sensitive information to an unauthorized actor. The firmware release has a dynamic token for each request submitted to the server, which makes repeating requests and analysis complex enough. Nevertheless, it's possible and during the analysis it was discovered that it also has an issue with the access-control matrix on the server-side. It was found that a user with low rights can get information from endpoints that should not be available to this user.
Dieser Datensatz: Live-Anbindung— zuletzt abgerufen: 7. November 2026 um 02:35.
Hersteller
Produkte
Ecograph T, Ecograph T Neutral/Private Label, Memograph M, Memograph M Neutral/Private Label
bis Version >=V2.0.0 (08/2015)
Veröffentlicht
19. November 2020
Zuletzt geändert
17. Juni 2026
Direkt aus NVD, CISA oder vom Hersteller übernommen — teils auf Englisch, unverändert gegenüber der Quelle.
Endress+Hauser Ecograph T (Neutral/Private Label) (RSG35, ORSG35) and Memograph M (Neutral/Private Label) (RSG45, ORSG45) with Firmware version V2.0.0 and above is prone to exposure of sensitive information to an unauthorized actor. The firmware release has a dynamic token for each request submitted to the server, which makes repeating requests and analysis complex enough. Nevertheless, it's possible and during the analysis it was discovered that it also has an issue with the access-control matrix on the server-side. It was found that a user with low rights can get information from endpoints that should not be available to this user.
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N
Attack Vector
NETWORK
Privileges Required
NONE
User Interaction
REQUIRED
Vertraulichkeit
Hoch
Integrität
Keine
Verfügbarkeit
Keine
Ausnutzungswahrscheinlichkeit innerhalb von 30 Tagen
0.8%
Perzentil
58e
Quelle: FIRST.org, aktualisiert am 6. November 2026.
Customers should configure a perimeter firewall to block traffic from untrusted networks and users to the device. These recommendations will be incorporated into the device documentation (operating instructions) Change default password for operator, service and admin account. Endress+Hauser will not change this behavior. Customers are recommended to take the measures for Temporary Fix / Mitigation as described above.
Unsere eigene Einordnung und unser Kontext zu den obigen Quelldaten.
IACS-Radar-Einordnung
Unsere eigene Einordnung und unser Kontext zu dieser Schwachstelle — keine offizielle Quelle.
IACS-Radar-Prioritätswert
Basierend auf CVSS 6.5, EPSS 0.8%, industrielle Relevanz 40/100.
Kombiniert CVSS, EPSS, KEV-Status, industrielle Relevanz und Expositionsrelevanz — eine Ergänzung, kein Ersatz für die einzelnen Werte darunter und darüber.
Voraussetzungen für eine Ausnutzung
Operative Auswirkungen & Energierelevanz
Begrenzte Auswirkung auf die Verfügbarkeit; das Risiko liegt vor allem bei der Vertraulichkeit oder Integrität von Prozessdaten.
Keine starken energiesektorspezifischen Signale erkannt; allgemeine OT-/ICS-Relevanz.
Empfohlene defensive Maßnahmen
Industrieller Relevanzwert
Die Einstufung ist vorläufig; eine manuelle Überprüfung durch einen OT-Security-Analysten wird empfohlen.
Klassifiziert von IACS Radar-analysepijplijn (geautomatiseerd) am 7. November 2026.
IEC-62443-Zuordnung
Automatische IACS-Radar-Einordnung anhand der gemeldeten CWE-Schwächeklassifizierung; keine offizielle Zertifizierungsaussage.