Specific versions of the Java driver that support client-side field level encryption (CSFLE) fail to perform correct host name verification on the KMS server’s certificate. This vulnerability in combination with a privileged network position active MITM attack could result in interception of traffic between the Java driver and the KMS service rendering Field Level Encryption ineffective. This issue was discovered during internal testing and affects all versions of the Java driver that support CSFLE. The Java async, Scala, and reactive streams drivers are not impacted. This vulnerability does not impact driver traffic payloads with CSFLE-supported key services originating from applications residing inside the AWS, GCP, and Azure network fabrics due to compensating controls in these environments. This issue does not impact driver workloads that don’t use Field Level Encryption.
Dieser Datensatz: Live-Anbindung— zuletzt abgerufen: 24. September 2026 um 05:08.
Direkt aus NVD, CISA oder vom Hersteller übernommen — teils auf Englisch, unverändert gegenüber der Quelle.
Specific versions of the Java driver that support client-side field level encryption (CSFLE) fail to perform correct host name verification on the KMS server’s certificate. This vulnerability in combination with a privileged network position active MITM attack could result in interception of traffic between the Java driver and the KMS service rendering Field Level Encryption ineffective. This issue was discovered during internal testing and affects all versions of the Java driver that support CSFLE. The Java async, Scala, and reactive streams drivers are not impacted. This vulnerability does not impact driver traffic payloads with CSFLE-supported key services originating from applications residing inside the AWS, GCP, and Azure network fabrics due to compensating controls in these environments. This issue does not impact driver workloads that don’t use Field Level Encryption.
CVSS:3.1/AV:A/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:N
Attack Vector
NETWORK
Privileges Required
NONE
User Interaction
REQUIRED
Vertraulichkeit
Hoch
Integrität
Hoch
Verfügbarkeit
Keine
Ausnutzungswahrscheinlichkeit innerhalb von 30 Tagen
0.4%
Perzentil
37e
Quelle: FIRST.org, aktualisiert am 23. September 2026.
ABB recommends the following mitigation measures: - Replace bundled MongoDB with a supported version if IIoT services are required: - Where IIoT functionality is required, the bundled MongoDB instance can be replaced with a supported and patched version through manual configuration. - The following zenon online help section explains the process of installing and using your own MongoDB database: zenHelpViewer - Uninstall IIoT Services wherever it’s not required: - If IIoT Services are not required, they can be removed using the Control panel uninstaller. This eliminates the dependency on MongoDB without affecting other zenon components. Refer to section “General security recommendations” for further advise on how to keep your system secure.
Unsere eigene Einordnung und unser Kontext zu den obigen Quelldaten.
IACS-Radar-Einordnung
Unsere eigene Einordnung und unser Kontext zu dieser Schwachstelle — keine offizielle Quelle.
IACS-Radar-Prioritätswert
Basierend auf CVSS 6.4, EPSS 0.4%, industrielle Relevanz 55/100.
Kombiniert CVSS, EPSS, KEV-Status, industrielle Relevanz und Expositionsrelevanz — eine Ergänzung, kein Ersatz für die einzelnen Werte darunter und darüber.
Voraussetzungen für eine Ausnutzung
Operative Auswirkungen & Energierelevanz
Begrenzte Auswirkung auf die Verfügbarkeit; das Risiko liegt vor allem bei der Vertraulichkeit oder Integrität von Prozessdaten.
Als relevant für den Energiesektor eingestuft aufgrund von: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Der Hersteller „ABB“ ist ein bekannter Lieferant von Ausrüstung für den Energiesektor.
Empfohlene defensive Maßnahmen
Industrieller Relevanzwert
Die Einstufung ist vorläufig; eine manuelle Überprüfung durch einen OT-Security-Analysten wird empfohlen.
Klassifiziert von IACS Radar-analysepijplijn (geautomatiseerd) am 24. September 2026.
IEC-62443-Zuordnung
Automatische IACS-Radar-Einordnung anhand der gemeldeten CWE-Schwächeklassifizierung; keine offizielle Zertifizierungsaussage.