CVE-2025-38721
In the Linux kernel, the following vulnerability has been resolved: netfilter: ctnetlink: fix refcount leak on table dump There is a reference count leak in ctnetlink_dump_table(): if (res < 0) { nf_conntrack_get(&ct->ct_general); // HERE cb->args[1] = (unsigned long)ct; ... While its very unlikely, its possible that ct == last. If this happens, then the refcount of ct was already incremented. This 2nd increment is never undone. This prevents the conntrack object from being released, which in turn keeps prevents cnet->count from dropping back to 0. This will then block the netns dismantle (or conntrack rmmod) as nf_conntrack_cleanup_net_list() will wait forever. This can be reproduced by running conntrack_resize.sh selftest in a loop. It takes ~20 minutes for me on a preemptible kernel on average before I see a runaway kworker spinning in nf_conntrack_cleanup_net_list. One fix would to change this to: if (res < 0) { if (ct != last) nf_conntrack_get(&ct->ct_general); But this reference counting isn't needed in the first place. We can just store a cookie value instead. A followup patch will do the same for ctnetlink_exp_dump_table, it looks to me as if this has the same problem and like ctnetlink_dump_table, we only need a 'skip hint', not the actual object so we can apply the same cookie strategy there as well.
Dieser Datensatz: Live-Anbindung— zuletzt abgerufen: 24. September 2026 um 05:10.
Direkt aus NVD, CISA oder vom Hersteller übernommen — teils auf Englisch, unverändert gegenüber der Quelle.
In the Linux kernel, the following vulnerability has been resolved: netfilter: ctnetlink: fix refcount leak on table dump There is a reference count leak in ctnetlink_dump_table(): if (res < 0) { nf_conntrack_get(&ct->ct_general); // HERE cb->args[1] = (unsigned long)ct; ... While its very unlikely, its possible that ct == last. If this happens, then the refcount of ct was already incremented. This 2nd increment is never undone. This prevents the conntrack object from being released, which in turn keeps prevents cnet->count from dropping back to 0. This will then block the netns dismantle (or conntrack rmmod) as nf_conntrack_cleanup_net_list() will wait forever. This can be reproduced by running conntrack_resize.sh selftest in a loop. It takes ~20 minutes for me on a preemptible kernel on average before I see a runaway kworker spinning in nf_conntrack_cleanup_net_list. One fix would to change this to: if (res < 0) { if (ct != last) nf_conntrack_get(&ct->ct_general); But this reference counting isn't needed in the first place. We can just store a cookie value instead. A followup patch will do the same for ctnetlink_exp_dump_table, it looks to me as if this has the same problem and like ctnetlink_dump_table, we only need a 'skip hint', not the actual object so we can apply the same cookie strategy there as well.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Attack Vector
LOCAL
Privileges Required
LOW
User Interaction
NONE
Vertraulichkeit
Keine
Integrität
Keine
Verfügbarkeit
Hoch
Ausnutzungswahrscheinlichkeit innerhalb von 30 Tagen
0.2%
Perzentil
6e
Quelle: FIRST.org, aktualisiert am 23. September 2026.
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
Unsere eigene Einordnung und unser Kontext zu den obigen Quelldaten.
IACS-Radar-Einordnung
Unsere eigene Einordnung und unser Kontext zu dieser Schwachstelle — keine offizielle Quelle.
IACS-Radar-Prioritätswert
Basierend auf CVSS 5.5, EPSS 0.2%, industrielle Relevanz 55/100.
Kombiniert CVSS, EPSS, KEV-Status, industrielle Relevanz und Expositionsrelevanz — eine Ergänzung, kein Ersatz für die einzelnen Werte darunter und darüber.
Voraussetzungen für eine Ausnutzung
Operative Auswirkungen & Energierelevanz
Möglicher Verlust der Sicht auf oder der Kontrolle über den Prozess bei erfolgreicher Ausnutzung.
Als relevant für den Energiesektor eingestuft aufgrund von: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Der Hersteller „Siemens“ ist ein bekannter Lieferant von Ausrüstung für den Energiesektor.
Empfohlene defensive Maßnahmen
Industrieller Relevanzwert
Die Einstufung ist vorläufig; eine manuelle Überprüfung durch einen OT-Security-Analysten wird empfohlen.
Klassifiziert von IACS Radar-analysepijplijn (geautomatiseerd) am 24. September 2026.
IEC-62443-Zuordnung
Automatische IACS-Radar-Einordnung anhand der gemeldeten CWE-Schwächeklassifizierung; keine offizielle Zertifizierungsaussage.