Schwachstellen werden geladen…
Schwachstellen werden geladen…
CVE-2025-39724
In the Linux kernel, the following vulnerability has been resolved: serial: 8250: fix panic due to PSLVERR When the PSLVERR_RESP_EN parameter is set to 1, the device generates an error response if an attempt is made to read an empty RBR (Receive Buffer Register) while the FIFO is enabled. In serial8250_do_startup(), calling serial_port_out(port, UART_LCR, UART_LCR_WLEN8) triggers dw8250_check_lcr(), which invokes dw8250_force_idle() and serial8250_clear_and_reinit_fifos(). The latter function enables the FIFO via serial_out(p, UART_FCR, p->fcr). Execution proceeds to the serial_port_in(port, UART_RX). This satisfies the PSLVERR trigger condition. When another CPU (e.g., using printk()) is accessing the UART (UART is busy), the current CPU fails the check (value & ~UART_LCR_SPAR) == (lcr & ~UART_LCR_SPAR) in dw8250_check_lcr(), causing it to enter dw8250_force_idle(). Put serial_port_out(port, UART_LCR, UART_LCR_WLEN8) under the port->lock to fix this issue. Panic backtrace: [ 0.442336] Oops - unknown exception [#1] [ 0.442343] epc : dw8250_serial_in32+0x1e/0x4a [ 0.442351] ra : serial8250_do_startup+0x2c8/0x88e ... [ 0.442416] console_on_rootfs+0x26/0x70
Dieser Datensatz: Live-Anbindung— zuletzt abgerufen: 24. September 2026 um 05:07.
Direkt aus NVD, CISA oder vom Hersteller übernommen — teils auf Englisch, unverändert gegenüber der Quelle.
In the Linux kernel, the following vulnerability has been resolved: serial: 8250: fix panic due to PSLVERR When the PSLVERR_RESP_EN parameter is set to 1, the device generates an error response if an attempt is made to read an empty RBR (Receive Buffer Register) while the FIFO is enabled. In serial8250_do_startup(), calling serial_port_out(port, UART_LCR, UART_LCR_WLEN8) triggers dw8250_check_lcr(), which invokes dw8250_force_idle() and serial8250_clear_and_reinit_fifos(). The latter function enables the FIFO via serial_out(p, UART_FCR, p->fcr). Execution proceeds to the serial_port_in(port, UART_RX). This satisfies the PSLVERR trigger condition. When another CPU (e.g., using printk()) is accessing the UART (UART is busy), the current CPU fails the check (value & ~UART_LCR_SPAR) == (lcr & ~UART_LCR_SPAR) in dw8250_check_lcr(), causing it to enter dw8250_force_idle(). Put serial_port_out(port, UART_LCR, UART_LCR_WLEN8) under the port->lock to fix this issue. Panic backtrace: [ 0.442336] Oops - unknown exception [#1] [ 0.442343] epc : dw8250_serial_in32+0x1e/0x4a [ 0.442351] ra : serial8250_do_startup+0x2c8/0x88e ... [ 0.442416] console_on_rootfs+0x26/0x70
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Attack Vector
LOCAL
Privileges Required
LOW
User Interaction
NONE
Vertraulichkeit
Keine
Integrität
Keine
Verfügbarkeit
Hoch
Ausnutzungswahrscheinlichkeit innerhalb von 30 Tagen
0.2%
Perzentil
7e
Quelle: FIRST.org, aktualisiert am 23. September 2026.
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
Unsere eigene Einordnung und unser Kontext zu den obigen Quelldaten.
IACS-Radar-Einordnung
Unsere eigene Einordnung und unser Kontext zu dieser Schwachstelle — keine offizielle Quelle.
IACS-Radar-Prioritätswert
Basierend auf CVSS 5.5, EPSS 0.2%, industrielle Relevanz 55/100.
Kombiniert CVSS, EPSS, KEV-Status, industrielle Relevanz und Expositionsrelevanz — eine Ergänzung, kein Ersatz für die einzelnen Werte darunter und darüber.
Voraussetzungen für eine Ausnutzung
Operative Auswirkungen & Energierelevanz
Möglicher Verlust der Sicht auf oder der Kontrolle über den Prozess bei erfolgreicher Ausnutzung.
Als relevant für den Energiesektor eingestuft aufgrund von: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Der Hersteller „Siemens“ ist ein bekannter Lieferant von Ausrüstung für den Energiesektor.
Empfohlene defensive Maßnahmen
Industrieller Relevanzwert
Die Einstufung ist vorläufig; eine manuelle Überprüfung durch einen OT-Security-Analysten wird empfohlen.
Klassifiziert von IACS Radar-analysepijplijn (geautomatiseerd) am 24. September 2026.
IEC-62443-Zuordnung
Automatische IACS-Radar-Einordnung anhand der gemeldeten CWE-Schwächeklassifizierung; keine offizielle Zertifizierungsaussage.