Schwachstellen werden geladen…
Schwachstellen werden geladen…
CVE-2025-39773
In the Linux kernel, the following vulnerability has been resolved: net: bridge: fix soft lockup in br_multicast_query_expired() When set multicast_query_interval to a large value, the local variable 'time' in br_multicast_send_query() may overflow. If the time is smaller than jiffies, the timer will expire immediately, and then call mod_timer() again, which creates a loop and may trigger the following soft lockup issue. watchdog: BUG: soft lockup - CPU#1 stuck for 221s! [rb_consumer:66] CPU: 1 UID: 0 PID: 66 Comm: rb_consumer Not tainted 6.16.0+ #259 PREEMPT(none) Call Trace: <IRQ> __netdev_alloc_skb+0x2e/0x3a0 br_ip6_multicast_alloc_query+0x212/0x1b70 __br_multicast_send_query+0x376/0xac0 br_multicast_send_query+0x299/0x510 br_multicast_query_expired.constprop.0+0x16d/0x1b0 call_timer_fn+0x3b/0x2a0 __run_timers+0x619/0x950 run_timer_softirq+0x11c/0x220 handle_softirqs+0x18e/0x560 __irq_exit_rcu+0x158/0x1a0 sysvec_apic_timer_interrupt+0x76/0x90 </IRQ> This issue can be reproduced with: ip link add br0 type bridge echo 1 > /sys/class/net/br0/bridge/multicast_querier echo 0xffffffffffffffff > /sys/class/net/br0/bridge/multicast_query_interval ip link set dev br0 up The multicast_startup_query_interval can also cause this issue. Similar to the commit 99b40610956a ("net: bridge: mcast: add and enforce query interval minimum"), add check for the query interval maximum to fix this issue.
Dieser Datensatz: Live-Anbindung— zuletzt abgerufen: 24. September 2026 um 05:06.
Direkt aus NVD, CISA oder vom Hersteller übernommen — teils auf Englisch, unverändert gegenüber der Quelle.
In the Linux kernel, the following vulnerability has been resolved: net: bridge: fix soft lockup in br_multicast_query_expired() When set multicast_query_interval to a large value, the local variable 'time' in br_multicast_send_query() may overflow. If the time is smaller than jiffies, the timer will expire immediately, and then call mod_timer() again, which creates a loop and may trigger the following soft lockup issue. watchdog: BUG: soft lockup - CPU#1 stuck for 221s! [rb_consumer:66] CPU: 1 UID: 0 PID: 66 Comm: rb_consumer Not tainted 6.16.0+ #259 PREEMPT(none) Call Trace: <IRQ> __netdev_alloc_skb+0x2e/0x3a0 br_ip6_multicast_alloc_query+0x212/0x1b70 __br_multicast_send_query+0x376/0xac0 br_multicast_send_query+0x299/0x510 br_multicast_query_expired.constprop.0+0x16d/0x1b0 call_timer_fn+0x3b/0x2a0 __run_timers+0x619/0x950 run_timer_softirq+0x11c/0x220 handle_softirqs+0x18e/0x560 __irq_exit_rcu+0x158/0x1a0 sysvec_apic_timer_interrupt+0x76/0x90 </IRQ> This issue can be reproduced with: ip link add br0 type bridge echo 1 > /sys/class/net/br0/bridge/multicast_querier echo 0xffffffffffffffff > /sys/class/net/br0/bridge/multicast_query_interval ip link set dev br0 up The multicast_startup_query_interval can also cause this issue. Similar to the commit 99b40610956a ("net: bridge: mcast: add and enforce query interval minimum"), add check for the query interval maximum to fix this issue.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Attack Vector
LOCAL
Privileges Required
LOW
User Interaction
NONE
Vertraulichkeit
Keine
Integrität
Keine
Verfügbarkeit
Hoch
Ausnutzungswahrscheinlichkeit innerhalb von 30 Tagen
0.1%
Perzentil
2e
Quelle: FIRST.org, aktualisiert am 23. September 2026.
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
Unsere eigene Einordnung und unser Kontext zu den obigen Quelldaten.
IACS-Radar-Einordnung
Unsere eigene Einordnung und unser Kontext zu dieser Schwachstelle — keine offizielle Quelle.
IACS-Radar-Prioritätswert
Basierend auf CVSS 5.5, EPSS 0.1%, industrielle Relevanz 55/100.
Kombiniert CVSS, EPSS, KEV-Status, industrielle Relevanz und Expositionsrelevanz — eine Ergänzung, kein Ersatz für die einzelnen Werte darunter und darüber.
Voraussetzungen für eine Ausnutzung
Operative Auswirkungen & Energierelevanz
Möglicher Verlust der Sicht auf oder der Kontrolle über den Prozess bei erfolgreicher Ausnutzung.
Als relevant für den Energiesektor eingestuft aufgrund von: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Der Hersteller „Siemens“ ist ein bekannter Lieferant von Ausrüstung für den Energiesektor.
Empfohlene defensive Maßnahmen
Industrieller Relevanzwert
Die Einstufung ist vorläufig; eine manuelle Überprüfung durch einen OT-Security-Analysten wird empfohlen.
Klassifiziert von IACS Radar-analysepijplijn (geautomatiseerd) am 24. September 2026.
IEC-62443-Zuordnung
Automatische IACS-Radar-Einordnung anhand der gemeldeten CWE-Schwächeklassifizierung; keine offizielle Zertifizierungsaussage.