CVE-2025-40816
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable.
Dieser Datensatz: Live-Anbindung— zuletzt abgerufen: 7. November 2026 um 14:52.
Hersteller
Veröffentlicht
11. November 2025
Zuletzt geändert
13. Oktober 2026
Direkt aus NVD, CISA oder vom Hersteller übernommen — teils auf Englisch, unverändert gegenüber der Quelle.
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA2) (All versions < V1.84.05), LOGO! 12/24RCEo (6ED1052-2MD08-0BA2) (All versions < V1.84.05), LOGO! 230RCE (6ED1052-1FB08-0BA2) (All versions < V1.84.05), LOGO! 230RCEo (6ED1052-2FB08-0BA2) (All versions < V1.84.05), LOGO! 24CE (6ED1052-1CC08-0BA2) (All versions < V1.84.05), LOGO! 24CEo (6ED1052-2CC08-0BA2) (All versions < V1.84.05), LOGO! 24RCE (6ED1052-1HB08-0BA2) (All versions < V1.84.05), LOGO! 24RCEo (6ED1052-2HB08-0BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA2) (All versions < V1.84.05), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA2) (All versions < V1.84.05). Affected devices do not conduct certain validations when interacting with them. This could allow an unauthenticated remote attacker to manipulate the devices IP address, which means the device would not be reachable.
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H
Attack Vector
NETWORK
Privileges Required
NONE
User Interaction
NONE
Vertraulichkeit
Begrenzt
Integrität
Begrenzt
Verfügbarkeit
Hoch
Ausnutzungswahrscheinlichkeit innerhalb von 30 Tagen
0.2%
Perzentil
12e
Quelle: FIRST.org, aktualisiert am 6. November 2026.
Restrict network access to port 10006/udp to trusted IP addresses.
Unsere eigene Einordnung und unser Kontext zu den obigen Quelldaten.
IACS-Radar-Einordnung
Unsere eigene Einordnung und unser Kontext zu dieser Schwachstelle — keine offizielle Quelle.
IACS-Radar-Prioritätswert
Basierend auf CVSS 7.6, EPSS 0.2%, industrielle Relevanz 55/100.
Kombiniert CVSS, EPSS, KEV-Status, industrielle Relevanz und Expositionsrelevanz — eine Ergänzung, kein Ersatz für die einzelnen Werte darunter und darüber.
Voraussetzungen für eine Ausnutzung
Operative Auswirkungen & Energierelevanz
Möglicher Verlust der Sicht auf oder der Kontrolle über den Prozess bei erfolgreicher Ausnutzung.
Als relevant für den Energiesektor eingestuft aufgrund von: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Der Hersteller „Siemens“ ist ein bekannter Lieferant von Ausrüstung für den Energiesektor.
Empfohlene defensive Maßnahmen
Industrieller Relevanzwert
Die Einstufung ist vorläufig; eine manuelle Überprüfung durch einen OT-Security-Analysten wird empfohlen.
Klassifiziert von IACS Radar-analysepijplijn (geautomatiseerd) am 7. November 2026.
IEC-62443-Zuordnung
Automatische IACS-Radar-Einordnung anhand der gemeldeten CWE-Schwächeklassifizierung; keine offizielle Zertifizierungsaussage.