Schwachstellen werden geladen…
Schwachstellen werden geladen…
CVE-2025-40946
A vulnerability has been identified in blueplanet 100 NX3 M8 (All versions), blueplanet 100 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 105 TL3 (All versions < V3.92), blueplanet 105 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 110 TL3 (All versions < V3.92), blueplanet 125 NX3 M10 (All versions), blueplanet 125 TL3 (All versions < V3.92), blueplanet 125 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 137 TL3 (All versions < V3.92), blueplanet 150 TL3 (All versions < V3.92), blueplanet 150 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 155 TL3 (All versions < V3.92), blueplanet 155 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 165 TL3 (All versions < V3.92), blueplanet 165 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 3.0 TL3-60.0 TL3 (All versions), blueplanet 87.0 TL3 (All versions < V3.92), blueplanet 87.0 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 92.0 TL3 (All versions < V3.92), blueplanet 92.0 TL3 GEN2 (All versions < V6.1.4.9), blueplanet gridsave 110 TL3-S (All versions < V3.91), blueplanet gridsave 137 TL3-S (All versions < V3.91), blueplanet gridsave 92.0 TL3-S (All versions < V3.91). A CRC16-based algorithm for generating Technical Service credentials could allow an attacker to derive the credentials from the devices serial number and misuse them to gain unauthorized access.
Dieser Datensatz: Live-Anbindung— zuletzt abgerufen: 7. November 2026 um 14:52.
Hersteller
Veröffentlicht
12. Mai 2026
Zuletzt geändert
24. Oktober 2026
Direkt aus NVD, CISA oder vom Hersteller übernommen — teils auf Englisch, unverändert gegenüber der Quelle.
A vulnerability has been identified in blueplanet 100 NX3 M8 (All versions), blueplanet 100 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 105 TL3 (All versions < V3.92), blueplanet 105 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 110 TL3 (All versions < V3.92), blueplanet 125 NX3 M10 (All versions), blueplanet 125 TL3 (All versions < V3.92), blueplanet 125 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 137 TL3 (All versions < V3.92), blueplanet 150 TL3 (All versions < V3.92), blueplanet 150 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 155 TL3 (All versions < V3.92), blueplanet 155 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 165 TL3 (All versions < V3.92), blueplanet 165 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 3.0 TL3-60.0 TL3 (All versions), blueplanet 87.0 TL3 (All versions < V3.92), blueplanet 87.0 TL3 GEN2 (All versions < V6.1.4.9), blueplanet 92.0 TL3 (All versions < V3.92), blueplanet 92.0 TL3 GEN2 (All versions < V6.1.4.9), blueplanet gridsave 110 TL3-S (All versions < V3.91), blueplanet gridsave 137 TL3-S (All versions < V3.91), blueplanet gridsave 92.0 TL3-S (All versions < V3.91). A CRC16-based algorithm for generating Technical Service credentials could allow an attacker to derive the credentials from the devices serial number and misuse them to gain unauthorized access.
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H
Attack Vector
NETWORK
Privileges Required
NONE
User Interaction
NONE
Vertraulichkeit
Begrenzt
Integrität
Hoch
Verfügbarkeit
Hoch
Ausnutzungswahrscheinlichkeit innerhalb von 30 Tagen
0.2%
Perzentil
8e
Quelle: FIRST.org, aktualisiert am 6. November 2026.
Currently no fix is planned
Unsere eigene Einordnung und unser Kontext zu den obigen Quelldaten.
IACS-Radar-Einordnung
Unsere eigene Einordnung und unser Kontext zu dieser Schwachstelle — keine offizielle Quelle.
IACS-Radar-Prioritätswert
Basierend auf CVSS 8.3, EPSS 0.2%, industrielle Relevanz 55/100.
Kombiniert CVSS, EPSS, KEV-Status, industrielle Relevanz und Expositionsrelevanz — eine Ergänzung, kein Ersatz für die einzelnen Werte darunter und darüber.
Voraussetzungen für eine Ausnutzung
Operative Auswirkungen & Energierelevanz
Möglicher Verlust der Sicht auf oder der Kontrolle über den Prozess bei erfolgreicher Ausnutzung.
Als relevant für den Energiesektor eingestuft aufgrund von: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Der Hersteller „Siemens“ ist ein bekannter Lieferant von Ausrüstung für den Energiesektor.
Empfohlene defensive Maßnahmen
Industrieller Relevanzwert
Die Einstufung ist vorläufig; eine manuelle Überprüfung durch einen OT-Security-Analysten wird empfohlen.
Klassifiziert von IACS Radar-analysepijplijn (geautomatiseerd) am 7. November 2026.
IEC-62443-Zuordnung
Automatische IACS-Radar-Einordnung anhand der gemeldeten CWE-Schwächeklassifizierung; keine offizielle Zertifizierungsaussage.