CVE-2026-13584
Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Mitsubishi Electric MELSEC MX Controller MX-R model, MELSEC MX Controller MX-F model, Master/local module, CC-Link IE TSN interface board, Motion module, MELSEC iQ-L Series Motion Module, Motion Control Board, Block-type remote module, Block-type remote module with safety functions, Analog-Digital converter module, Digital-Analog converter module, CC-Link IE TSN compatible coupler, FPGA module, Tension meter, AC Servo MELSERVO-J5, AC Servo MELSERVO-JET, Liner Track System MTR-S series Linear track control module, Inverter FR-A800/F800/E800 Series, Industrial Robot CR800-D series controller Network Base Card, CC-Link IE TSN expansion unit, CC-Link IE TSN-CC-Link IE Field Network bridge module, CC-Link IE TSN-AnyWireASLINK bridge module, Energy Measuring Unit CC-Link IE TSN Communication Unit, GOT3000 Series, CC-Link IE TSN Communication Unit, Motion Control Software, CC-Link IE TSN Communication Software for Windows, Analysis Support Software MELSOFT VIMA, Master/Local module Designated communication LSI DeviceKit, Remote Station Communication LSI with GbE-PHY, CC-Link IE TSN Master/Local module Designated communication LSI SDK, and Remote station software development kit allows an attacker with access to a CC-Link IE TSN network to tamper with communication data (control input/output values) by sending specially crafted packets under specific timing conditions. This could allow the attacker to cause a denial-of-service (DoS) condition in the affected product by interfering with its control function or causing it to operate incorrectly.
Dieser Datensatz: Live-Anbindung— zuletzt abgerufen: 24. September 2026 um 04:16.
Direkt aus NVD, CISA oder vom Hersteller übernommen — teils auf Englisch, unverändert gegenüber der Quelle.
Improper Enforcement of Message Integrity During Transmission in a Communication Channel vulnerability in Mitsubishi Electric MELSEC MX Controller MX-R model, MELSEC MX Controller MX-F model, Master/local module, CC-Link IE TSN interface board, Motion module, MELSEC iQ-L Series Motion Module, Motion Control Board, Block-type remote module, Block-type remote module with safety functions, Analog-Digital converter module, Digital-Analog converter module, CC-Link IE TSN compatible coupler, FPGA module, Tension meter, AC Servo MELSERVO-J5, AC Servo MELSERVO-JET, Liner Track System MTR-S series Linear track control module, Inverter FR-A800/F800/E800 Series, Industrial Robot CR800-D series controller Network Base Card, CC-Link IE TSN expansion unit, CC-Link IE TSN-CC-Link IE Field Network bridge module, CC-Link IE TSN-AnyWireASLINK bridge module, Energy Measuring Unit CC-Link IE TSN Communication Unit, GOT3000 Series, CC-Link IE TSN Communication Unit, Motion Control Software, CC-Link IE TSN Communication Software for Windows, Analysis Support Software MELSOFT VIMA, Master/Local module Designated communication LSI DeviceKit, Remote Station Communication LSI with GbE-PHY, CC-Link IE TSN Master/Local module Designated communication LSI SDK, and Remote station software development kit allows an attacker with access to a CC-Link IE TSN network to tamper with communication data (control input/output values) by sending specially crafted packets under specific timing conditions. This could allow the attacker to cause a denial-of-service (DoS) condition in the affected product by interfering with its control function or causing it to operate incorrectly.
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:L
Attack Vector
NETWORK
Privileges Required
NONE
User Interaction
NONE
Vertraulichkeit
Keine
Integrität
Keine
Verfügbarkeit
Keine
Ausnutzungswahrscheinlichkeit innerhalb von 30 Tagen
0.1%
Perzentil
3e
Quelle: FIRST.org, aktualisiert am 23. September 2026.
For customers using the affected products, please refer to Mitsubishi Electric's security advisory, "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-005_en.pdf" and take the measures described there.
Unsere eigene Einordnung und unser Kontext zu den obigen Quelldaten.
IACS-Radar-Einordnung
Unsere eigene Einordnung und unser Kontext zu dieser Schwachstelle — keine offizielle Quelle.
IACS-Radar-Prioritätswert
Basierend auf CVSS 7.1, EPSS 0.1%, industrielle Relevanz 55/100.
Kombiniert CVSS, EPSS, KEV-Status, industrielle Relevanz und Expositionsrelevanz — eine Ergänzung, kein Ersatz für die einzelnen Werte darunter und darüber.
Voraussetzungen für eine Ausnutzung
Operative Auswirkungen & Energierelevanz
Begrenzte Auswirkung auf die Verfügbarkeit; das Risiko liegt vor allem bei der Vertraulichkeit oder Integrität von Prozessdaten.
Als relevant für den Energiesektor eingestuft aufgrund von: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Der Hersteller „Mitsubishi Electric“ ist ein bekannter Lieferant von Ausrüstung für den Energiesektor.
Empfohlene defensive Maßnahmen
Industrieller Relevanzwert
Die Einstufung ist vorläufig; eine manuelle Überprüfung durch einen OT-Security-Analysten wird empfohlen.
Klassifiziert von IACS Radar-analysepijplijn (geautomatiseerd) am 24. September 2026.
IEC-62443-Zuordnung
Automatische IACS-Radar-Einordnung anhand der gemeldeten CWE-Schwächeklassifizierung; keine offizielle Zertifizierungsaussage.