Schwachstellen werden geladen…
Schwachstellen werden geladen…
CVE-2026-23287
In the Linux kernel, the following vulnerability has been resolved: irqchip/sifive-plic: Fix frozen interrupt due to affinity setting PLIC ignores interrupt completion message for disabled interrupt, explained by the specification: The PLIC signals it has completed executing an interrupt handler by writing the interrupt ID it received from the claim to the claim/complete register. The PLIC does not check whether the completion ID is the same as the last claim ID for that target. If the completion ID does not match an interrupt source that is currently enabled for the target, the completion is silently ignored. This caused problems in the past, because an interrupt can be disabled while still being handled and plic_irq_eoi() had no effect. That was fixed by checking if the interrupt is disabled, and if so enable it, before sending the completion message. That check is done with irqd_irq_disabled(). However, that is not sufficient because the enable bit for the handling hart can be zero despite irqd_irq_disabled(d) being false. This can happen when affinity setting is changed while a hart is still handling the interrupt. This problem is easily reproducible by dumping a large file to uart (which generates lots of interrupts) and at the same time keep changing the uart interrupt's affinity setting. The uart port becomes frozen almost instantaneously. Fix this by checking PLIC's enable bit instead of irqd_irq_disabled().
Dieser Datensatz: Live-Anbindung— zuletzt abgerufen: 24. September 2026 um 05:08.
Direkt aus NVD, CISA oder vom Hersteller übernommen — teils auf Englisch, unverändert gegenüber der Quelle.
In the Linux kernel, the following vulnerability has been resolved: irqchip/sifive-plic: Fix frozen interrupt due to affinity setting PLIC ignores interrupt completion message for disabled interrupt, explained by the specification: The PLIC signals it has completed executing an interrupt handler by writing the interrupt ID it received from the claim to the claim/complete register. The PLIC does not check whether the completion ID is the same as the last claim ID for that target. If the completion ID does not match an interrupt source that is currently enabled for the target, the completion is silently ignored. This caused problems in the past, because an interrupt can be disabled while still being handled and plic_irq_eoi() had no effect. That was fixed by checking if the interrupt is disabled, and if so enable it, before sending the completion message. That check is done with irqd_irq_disabled(). However, that is not sufficient because the enable bit for the handling hart can be zero despite irqd_irq_disabled(d) being false. This can happen when affinity setting is changed while a hart is still handling the interrupt. This problem is easily reproducible by dumping a large file to uart (which generates lots of interrupts) and at the same time keep changing the uart interrupt's affinity setting. The uart port becomes frozen almost instantaneously. Fix this by checking PLIC's enable bit instead of irqd_irq_disabled().
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Attack Vector
LOCAL
Privileges Required
LOW
User Interaction
NONE
Vertraulichkeit
Keine
Integrität
Keine
Verfügbarkeit
Hoch
Ausnutzungswahrscheinlichkeit innerhalb von 30 Tagen
0.1%
Perzentil
2e
Quelle: FIRST.org, aktualisiert am 23. September 2026.
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
Unsere eigene Einordnung und unser Kontext zu den obigen Quelldaten.
IACS-Radar-Einordnung
Unsere eigene Einordnung und unser Kontext zu dieser Schwachstelle — keine offizielle Quelle.
IACS-Radar-Prioritätswert
Basierend auf CVSS 5.5, EPSS 0.1%, industrielle Relevanz 55/100.
Kombiniert CVSS, EPSS, KEV-Status, industrielle Relevanz und Expositionsrelevanz — eine Ergänzung, kein Ersatz für die einzelnen Werte darunter und darüber.
Voraussetzungen für eine Ausnutzung
Operative Auswirkungen & Energierelevanz
Möglicher Verlust der Sicht auf oder der Kontrolle über den Prozess bei erfolgreicher Ausnutzung.
Als relevant für den Energiesektor eingestuft aufgrund von: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Der Hersteller „Siemens“ ist ein bekannter Lieferant von Ausrüstung für den Energiesektor.
Empfohlene defensive Maßnahmen
Industrieller Relevanzwert
Die Einstufung ist vorläufig; eine manuelle Überprüfung durch einen OT-Security-Analysten wird empfohlen.
Klassifiziert von IACS Radar-analysepijplijn (geautomatiseerd) am 24. September 2026.
IEC-62443-Zuordnung
Automatische IACS-Radar-Einordnung anhand der gemeldeten CWE-Schwächeklassifizierung; keine offizielle Zertifizierungsaussage.