Schwachstellen werden geladen…
Schwachstellen werden geladen…
CVE-2026-23381
In the Linux kernel, the following vulnerability has been resolved: net: bridge: fix nd_tbl NULL dereference when IPv6 is disabled When booting with the 'ipv6.disable=1' parameter, the nd_tbl is never initialized because inet6_init() exits before ndisc_init() is called which initializes it. Then, if neigh_suppress is enabled and an ICMPv6 Neighbor Discovery packet reaches the bridge, br_do_suppress_nd() will dereference ipv6_stub->nd_tbl which is NULL, passing it to neigh_lookup(). This causes a kernel NULL pointer dereference. BUG: kernel NULL pointer dereference, address: 0000000000000268 Oops: 0000 [#1] PREEMPT SMP NOPTI [...] RIP: 0010:neigh_lookup+0x16/0xe0 [...] Call Trace: <IRQ> ? neigh_lookup+0x16/0xe0 br_do_suppress_nd+0x160/0x290 [bridge] br_handle_frame_finish+0x500/0x620 [bridge] br_handle_frame+0x353/0x440 [bridge] __netif_receive_skb_core.constprop.0+0x298/0x1110 __netif_receive_skb_one_core+0x3d/0xa0 process_backlog+0xa0/0x140 __napi_poll+0x2c/0x170 net_rx_action+0x2c4/0x3a0 handle_softirqs+0xd0/0x270 do_softirq+0x3f/0x60 Fix this by replacing IS_ENABLED(IPV6) call with ipv6_mod_enabled() in the callers. This is in essence disabling NS/NA suppression when IPv6 is disabled.
Dieser Datensatz: Live-Anbindung— zuletzt abgerufen: 24. September 2026 um 05:08.
Direkt aus NVD, CISA oder vom Hersteller übernommen — teils auf Englisch, unverändert gegenüber der Quelle.
In the Linux kernel, the following vulnerability has been resolved: net: bridge: fix nd_tbl NULL dereference when IPv6 is disabled When booting with the 'ipv6.disable=1' parameter, the nd_tbl is never initialized because inet6_init() exits before ndisc_init() is called which initializes it. Then, if neigh_suppress is enabled and an ICMPv6 Neighbor Discovery packet reaches the bridge, br_do_suppress_nd() will dereference ipv6_stub->nd_tbl which is NULL, passing it to neigh_lookup(). This causes a kernel NULL pointer dereference. BUG: kernel NULL pointer dereference, address: 0000000000000268 Oops: 0000 [#1] PREEMPT SMP NOPTI [...] RIP: 0010:neigh_lookup+0x16/0xe0 [...] Call Trace: <IRQ> ? neigh_lookup+0x16/0xe0 br_do_suppress_nd+0x160/0x290 [bridge] br_handle_frame_finish+0x500/0x620 [bridge] br_handle_frame+0x353/0x440 [bridge] __netif_receive_skb_core.constprop.0+0x298/0x1110 __netif_receive_skb_one_core+0x3d/0xa0 process_backlog+0xa0/0x140 __napi_poll+0x2c/0x170 net_rx_action+0x2c4/0x3a0 handle_softirqs+0xd0/0x270 do_softirq+0x3f/0x60 Fix this by replacing IS_ENABLED(IPV6) call with ipv6_mod_enabled() in the callers. This is in essence disabling NS/NA suppression when IPv6 is disabled.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Attack Vector
LOCAL
Privileges Required
LOW
User Interaction
NONE
Vertraulichkeit
Keine
Integrität
Keine
Verfügbarkeit
Hoch
Ausnutzungswahrscheinlichkeit innerhalb von 30 Tagen
0.1%
Perzentil
2e
Quelle: FIRST.org, aktualisiert am 23. September 2026.
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
Unsere eigene Einordnung und unser Kontext zu den obigen Quelldaten.
IACS-Radar-Einordnung
Unsere eigene Einordnung und unser Kontext zu dieser Schwachstelle — keine offizielle Quelle.
IACS-Radar-Prioritätswert
Basierend auf CVSS 5.5, EPSS 0.1%, industrielle Relevanz 55/100.
Kombiniert CVSS, EPSS, KEV-Status, industrielle Relevanz und Expositionsrelevanz — eine Ergänzung, kein Ersatz für die einzelnen Werte darunter und darüber.
Voraussetzungen für eine Ausnutzung
Operative Auswirkungen & Energierelevanz
Möglicher Verlust der Sicht auf oder der Kontrolle über den Prozess bei erfolgreicher Ausnutzung.
Als relevant für den Energiesektor eingestuft aufgrund von: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Der Hersteller „Siemens“ ist ein bekannter Lieferant von Ausrüstung für den Energiesektor.
Empfohlene defensive Maßnahmen
Industrieller Relevanzwert
Die Einstufung ist vorläufig; eine manuelle Überprüfung durch einen OT-Security-Analysten wird empfohlen.
Klassifiziert von IACS Radar-analysepijplijn (geautomatiseerd) am 24. September 2026.
IEC-62443-Zuordnung
Automatische IACS-Radar-Einordnung anhand der gemeldeten CWE-Schwächeklassifizierung; keine offizielle Zertifizierungsaussage.