CVE-2026-44414
In den Produkten „Industrial Edge Cloud Device (IECD)“, „Industrial Edge Device Kit – arm64 V1.10“, „Industrial Edge Device Kit – arm64 V1.11“, „Industrial Edge Device Kit – arm64 V1.12“ sowie Industrial Edge Device Kit – arm64 V1.13, Industrial Edge Device Kit – arm64 V1.14, Industrial Edge Device Kit – arm64 V1.15, Industrial Edge Device Kit – arm64 V1.16, Industrial Edge Device Kit – arm64 V1.17, Industrielles Edge-Geräte-Kit – arm64 V1.18, Industrielles Edge-Geräte-Kit – arm64 V1.19, Industrielles Edge-Geräte-Kit – arm64 V1.20, Industrielles Edge-Geräte-Kit – arm64 V1.21, Industrielles Edge-Geräte-Kit – arm64 V1.22, Industrielles Edge-Geräte-Kit – arm64 V1.23, Industrielles Edge-Geräte-Kit – arm64 V1.24, Industrielles Edge-Geräte-Kit – arm64 V1.25, Industrielles Edge-Geräte-Kit – arm64 V1.26, Industrielles Edge-Geräte-Kit – arm64 V1.27, Industrielles Edge-Geräte-Kit – arm64 V1.28, Industrielles Edge-Geräte-Kit – arm64 V1.5, Industrielles Edge-Geräte-Kit – arm64 V1.6, Industrielles Edge-Geräte-Kit – arm64 V1.7, Industrielles Edge-Geräte-Kit – arm64 V1.8, Industrielles Edge-Geräte-Kit – arm64 V1.9, Industrielles Edge-Geräte-Kit – x86-64 V1.10, Industrielles Edge-Geräte-Kit – x86-64 V1.11, Industrielles Edge-Geräte-Kit – x86-64 V1.12, Industrielles Edge-Geräte-Kit – x86-64 V1.13, Industrielles Edge-Geräte-Kit – x86-64 V1.14, Industrielles Edge-Geräte-Kit – x86-64 V1.15, Industrielles Edge-Geräte-Kit – x86-64 V1.16, Industrielles Edge-Geräte-Kit – x86-64 V1.17, Industrielles Edge-Geräte-Kit – x86-64 V1.18, Industrielles Edge-Geräte-Kit – x86-64 V1.19, Industrielles Edge-Geräte-Kit – x86-64 V1.20, Industrielles Edge-Geräte-Kit – x86-64 V1.21, Industrielles Edge-Geräte-Kit – x86-64 V1.22, Industrielles Edge-Geräte-Kit – x86-64 V1.23, Industrielles Edge-Geräte-Kit – x86-64 V1.24, Industrielles Edge-Geräte-Kit – x86-64 V1.25, Industrielles Edge-Geräte-Kit – x86-64 V1.26, Industrielles Edge-Geräte-Kit – x86-64 V1.27, Industrielles Edge-Geräte-Kit – x86-64 V1.28, Industrial Edge Device Kit – x86-64 V1.5, Industrial Edge Device Kit – x86-64 V1.6, Industrial Edge Device Kit – x86-64 V1.7, Industrial Edge Device Kit – x86-64 V1.8, Industrial Edge Device Kit – x86-64 V1.9, Industrial Edge Own Device (IEOD), Industrial Edge Virtual Device (IEVD), SCALANCE LPE9413 (6GK5998-3GS01-2AC2), SCALANCE LPE9433 (6GK5998-3GS11-2AC2), SIMATIC IoT2050 Advanced IED (6ES7647-0BW00-1YA2), SIMATIC IoT2050 SM IED (6ES7647-0CW00-1AA2), SIMATIC IPC BX-21A Industrial Edge Device, SIMATIC IPC BX-39A Industrial Edge Device, SIMATIC IPC BX-59A Industrial Edge Device, SIMATIC IPC127E Industrial Edge Device, SIMATIC IPC227E Industrial Edge Device, SIMATIC IPC227G Industrial Edge Device, SIMATIC IPC427E Industrial Edge Device, SIMATIC IPC847E Industrial Edge Device. Die betroffenen Systeme schränken den Zugriff auf interne APIs und Pfade für authentifizierte Benutzer nicht ordnungsgemäß ein. Dies könnte es einem authentifizierten Angreifer aus der Ferne ermöglichen, auf sensible interne Informationen zuzugreifen, was im schlimmsten Fall dazu genutzt werden könnte, sich unbefugten Zugriff auf das System zu verschaffen.
Automatisch übersetzt mit DeepL. Der Originaltext steht unter Originale Quelleninformationen.
Dieser Datensatz: Live-Anbindung— zuletzt abgerufen: 7. November 2026 um 14:52.
Hersteller
Veröffentlicht
13. Oktober 2026
Zuletzt geändert
15. Oktober 2026
Direkt aus NVD, CISA oder vom Hersteller übernommen — teils auf Englisch, unverändert gegenüber der Quelle.
A vulnerability has been identified in Industrial Edge Cloud Device (IECD), Industrial Edge Device Kit - arm64 V1.10, Industrial Edge Device Kit - arm64 V1.11, Industrial Edge Device Kit - arm64 V1.12, Industrial Edge Device Kit - arm64 V1.13, Industrial Edge Device Kit - arm64 V1.14, Industrial Edge Device Kit - arm64 V1.15, Industrial Edge Device Kit - arm64 V1.16, Industrial Edge Device Kit - arm64 V1.17, Industrial Edge Device Kit - arm64 V1.18, Industrial Edge Device Kit - arm64 V1.19, Industrial Edge Device Kit - arm64 V1.20, Industrial Edge Device Kit - arm64 V1.21, Industrial Edge Device Kit - arm64 V1.22, Industrial Edge Device Kit - arm64 V1.23, Industrial Edge Device Kit - arm64 V1.24, Industrial Edge Device Kit - arm64 V1.25, Industrial Edge Device Kit - arm64 V1.26, Industrial Edge Device Kit - arm64 V1.27, Industrial Edge Device Kit - arm64 V1.28, Industrial Edge Device Kit - arm64 V1.5, Industrial Edge Device Kit - arm64 V1.6, Industrial Edge Device Kit - arm64 V1.7, Industrial Edge Device Kit - arm64 V1.8, Industrial Edge Device Kit - arm64 V1.9, Industrial Edge Device Kit - x86-64 V1.10, Industrial Edge Device Kit - x86-64 V1.11, Industrial Edge Device Kit - x86-64 V1.12, Industrial Edge Device Kit - x86-64 V1.13, Industrial Edge Device Kit - x86-64 V1.14, Industrial Edge Device Kit - x86-64 V1.15, Industrial Edge Device Kit - x86-64 V1.16, Industrial Edge Device Kit - x86-64 V1.17, Industrial Edge Device Kit - x86-64 V1.18, Industrial Edge Device Kit - x86-64 V1.19, Industrial Edge Device Kit - x86-64 V1.20, Industrial Edge Device Kit - x86-64 V1.21, Industrial Edge Device Kit - x86-64 V1.22, Industrial Edge Device Kit - x86-64 V1.23, Industrial Edge Device Kit - x86-64 V1.24, Industrial Edge Device Kit - x86-64 V1.25, Industrial Edge Device Kit - x86-64 V1.26, Industrial Edge Device Kit - x86-64 V1.27, Industrial Edge Device Kit - x86-64 V1.28, Industrial Edge Device Kit - x86-64 V1.5, Industrial Edge Device Kit - x86-64 V1.6, Industrial Edge Device Kit - x86-64 V1.7, Industrial Edge Device Kit - x86-64 V1.8, Industrial Edge Device Kit - x86-64 V1.9, Industrial Edge Own Device (IEOD), Industrial Edge Virtual Device (IEVD), SCALANCE LPE9413 (6GK5998-3GS01-2AC2), SCALANCE LPE9433 (6GK5998-3GS11-2AC2), SIMATIC IoT2050 Advanced IED (6ES7647-0BW00-1YA2), SIMATIC IoT2050 SM IED (6ES7647-0CW00-1AA2), SIMATIC IPC BX-21A Industrial Edge Device, SIMATIC IPC BX-39A Industrial Edge Device, SIMATIC IPC BX-59A Industrial Edge Device, SIMATIC IPC127E Industrial Edge Device, SIMATIC IPC227E Industrial Edge Device, SIMATIC IPC227G Industrial Edge Device, SIMATIC IPC427E Industrial Edge Device, SIMATIC IPC847E Industrial Edge Device. Affected systems do not properly restrict access to internal APIs and paths for authenticated users. This could allow an authenticated remote attacker to access sensitive internal information, which in the worst case could be leveraged to facilitate unauthorized access to the system.
CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:N
Attack Vector
NETWORK
Privileges Required
HIGH
User Interaction
NONE
Vertraulichkeit
Hoch
Integrität
Keine
Verfügbarkeit
Keine
Ausnutzungswahrscheinlichkeit innerhalb von 30 Tagen
0.5%
Perzentil
41e
Quelle: FIRST.org, aktualisiert am 6. November 2026.
Ensure network access to affected products is limited to trusted parties only
Unsere eigene Einordnung und unser Kontext zu den obigen Quelldaten.
IACS-Radar-Einordnung
Unsere eigene Einordnung und unser Kontext zu dieser Schwachstelle — keine offizielle Quelle.
IACS-Radar-Prioritätswert
Basierend auf CVSS 6.8, EPSS 0.5%, industrielle Relevanz 75/100.
Kombiniert CVSS, EPSS, KEV-Status, industrielle Relevanz und Expositionsrelevanz — eine Ergänzung, kein Ersatz für die einzelnen Werte darunter und darüber.
Voraussetzungen für eine Ausnutzung
Operative Auswirkungen & Energierelevanz
Begrenzte Auswirkung auf die Verfügbarkeit; das Risiko liegt vor allem bei der Vertraulichkeit oder Integrität von Prozessdaten.
Als relevant für den Energiesektor eingestuft aufgrund von: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Productbeschrijving komt overeen met de categorie "IED", een typisch OT/ICS-componenttype. Der Hersteller „Siemens“ ist ein bekannter Lieferant von Ausrüstung für den Energiesektor.
Empfohlene defensive Maßnahmen
Industrieller Relevanzwert
Automatisch als industriell relevant eingestuft anhand von CISA-/NVD-Signalen (siehe Gründe).
Klassifiziert von IACS Radar-analysepijplijn (geautomatiseerd) am 7. November 2026.
IEC-62443-Zuordnung
Automatische IACS-Radar-Einordnung anhand der gemeldeten CWE-Schwächeklassifizierung; keine offizielle Zertifizierungsaussage.