Schwachstellen werden geladen…
Schwachstellen werden geladen…
CVE-2026-53012
In the Linux kernel, the following vulnerability has been resolved: nexthop: fix IPv6 route referencing IPv4 nexthop syzbot reported a panic [1] [2]. When an IPv6 nexthop is replaced with an IPv4 nexthop, the has_v4 flag of all groups containing this nexthop is not updated. This is because nh_group_v4_update is only called when replacing AF_INET to AF_INET6, but the reverse direction (AF_INET6 to AF_INET) is missed. This allows a stale has_v4=false to bypass fib6_check_nexthop, causing IPv6 routes to be attached to groups that effectively contain only AF_INET members. Subsequent route lookups then call nexthop_fib6_nh() which returns NULL for the AF_INET member, leading to a NULL pointer dereference. Fix by calling nh_group_v4_update whenever the family changes, not just AF_INET to AF_INET6. Reproducer: # AF_INET6 blackhole ip -6 nexthop add id 1 blackhole # group with has_v4=false ip nexthop add id 100 group 1 # replace with AF_INET (no -6), has_v4 stays false ip nexthop replace id 1 blackhole # pass stale has_v4 check ip -6 route add 2001:db8::/64 nhid 100 # panic ping -6 2001:db8::1 [1] https://syzkaller.appspot.com/bug?id=e17283eb2f8dcf3dd9b47fe6f67a95f71faadad0 [2] https://syzkaller.appspot.com/bug?id=8699b6ae54c9f35837d925686208402949e12ef3
Dieser Datensatz: Live-Anbindung— zuletzt abgerufen: 24. September 2026 um 05:07.
Direkt aus NVD, CISA oder vom Hersteller übernommen — teils auf Englisch, unverändert gegenüber der Quelle.
In the Linux kernel, the following vulnerability has been resolved: nexthop: fix IPv6 route referencing IPv4 nexthop syzbot reported a panic [1] [2]. When an IPv6 nexthop is replaced with an IPv4 nexthop, the has_v4 flag of all groups containing this nexthop is not updated. This is because nh_group_v4_update is only called when replacing AF_INET to AF_INET6, but the reverse direction (AF_INET6 to AF_INET) is missed. This allows a stale has_v4=false to bypass fib6_check_nexthop, causing IPv6 routes to be attached to groups that effectively contain only AF_INET members. Subsequent route lookups then call nexthop_fib6_nh() which returns NULL for the AF_INET member, leading to a NULL pointer dereference. Fix by calling nh_group_v4_update whenever the family changes, not just AF_INET to AF_INET6. Reproducer: # AF_INET6 blackhole ip -6 nexthop add id 1 blackhole # group with has_v4=false ip nexthop add id 100 group 1 # replace with AF_INET (no -6), has_v4 stays false ip nexthop replace id 1 blackhole # pass stale has_v4 check ip -6 route add 2001:db8::/64 nhid 100 # panic ping -6 2001:db8::1 [1] https://syzkaller.appspot.com/bug?id=e17283eb2f8dcf3dd9b47fe6f67a95f71faadad0 [2] https://syzkaller.appspot.com/bug?id=8699b6ae54c9f35837d925686208402949e12ef3
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Attack Vector
LOCAL
Privileges Required
LOW
User Interaction
NONE
Vertraulichkeit
Keine
Integrität
Keine
Verfügbarkeit
Hoch
Ausnutzungswahrscheinlichkeit innerhalb von 30 Tagen
0.1%
Perzentil
3e
Quelle: FIRST.org, aktualisiert am 23. September 2026.
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
Unsere eigene Einordnung und unser Kontext zu den obigen Quelldaten.
IACS-Radar-Einordnung
Unsere eigene Einordnung und unser Kontext zu dieser Schwachstelle — keine offizielle Quelle.
IACS-Radar-Prioritätswert
Basierend auf CVSS 5.5, EPSS 0.1%, industrielle Relevanz 60/100; angehoben wegen Relevanz für Internet-Exposition.
Kombiniert CVSS, EPSS, KEV-Status, industrielle Relevanz und Expositionsrelevanz — eine Ergänzung, kein Ersatz für die einzelnen Werte darunter und darüber.
Voraussetzungen für eine Ausnutzung
Operative Auswirkungen & Energierelevanz
Möglicher Verlust der Sicht auf oder der Kontrolle über den Prozess bei erfolgreicher Ausnutzung.
Als relevant für den Energiesektor eingestuft aufgrund von: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Der Hersteller „Siemens“ ist ein bekannter Lieferant von Ausrüstung für den Energiesektor. Die Beschreibung nennt ein industrielles Protokoll: https.
Dieses Produkt verwendet Protokolle, die für die Analyse der Internet-Exposition relevant sind. Ein aus dem Internet erreichbarer Dienst ist nicht automatisch verwundbar.
Empfohlene defensive Maßnahmen
Industrieller Relevanzwert
Automatisch als industriell relevant eingestuft anhand von CISA-/NVD-Signalen (siehe Gründe).
Klassifiziert von IACS Radar-analysepijplijn (geautomatiseerd) am 24. September 2026.
IEC-62443-Zuordnung
Automatische IACS-Radar-Einordnung anhand der gemeldeten CWE-Schwächeklassifizierung; keine offizielle Zertifizierungsaussage.