Schwachstellen werden geladen…
Schwachstellen werden geladen…
CVE-2026-76287
In Splunk Enterprise versions below 10.4.4, a user that holds a role with the preview_data_management_pipeline capability or edit_data_management_pipeline_job capability could read or delete Data Management SPL2 preview jobs and results outside their ownership scope. The vulnerability is possible because the Data Management Representational State Transfer (REST) API verifies the required capability but does not verify that the requested preview job belongs to the requester. The affected Data Management REST API is available only when the Edge Processor feature is turned on. The Edge Processor feature is turned off by default. For more information see Set up a data management control plane (https://help.splunk.com/en/splunk-enterprise/process-data-at-the-edge/use-edge-processors-for-splunk-enterprise/10.4/getting-started/set-up-a-data-management-control-plane) and Getting sample data for previewing data transformations (https://help.splunk.com/en/splunk-enterprise/process-data-at-the-edge/use-edge-processors-for-splunk-enterprise/10.4/working-with-pipelines/getting-sample-data-for-previewing-data-transformations) in the Splunk documentation.
Dieser Datensatz: Live-Anbindung— zuletzt abgerufen: 8. November 2026 um 08:48.
Hersteller
Produkt
Veröffentlicht
22. Oktober 2026
Zuletzt geändert
30. Oktober 2026
Direkt aus NVD, CISA oder vom Hersteller übernommen — teils auf Englisch, unverändert gegenüber der Quelle.
In Splunk Enterprise versions below 10.4.4, a user that holds a role with the preview_data_management_pipeline capability or edit_data_management_pipeline_job capability could read or delete Data Management SPL2 preview jobs and results outside their ownership scope. The vulnerability is possible because the Data Management Representational State Transfer (REST) API verifies the required capability but does not verify that the requested preview job belongs to the requester. The affected Data Management REST API is available only when the Edge Processor feature is turned on. The Edge Processor feature is turned off by default. For more information see Set up a data management control plane (https://help.splunk.com/en/splunk-enterprise/process-data-at-the-edge/use-edge-processors-for-splunk-enterprise/10.4/getting-started/set-up-a-data-management-control-plane) and Getting sample data for previewing data transformations (https://help.splunk.com/en/splunk-enterprise/process-data-at-the-edge/use-edge-processors-for-splunk-enterprise/10.4/working-with-pipelines/getting-sample-data-for-previewing-data-transformations) in the Splunk documentation.
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N
Attack Vector
NETWORK
Privileges Required
LOW
User Interaction
NONE
Vertraulichkeit
Begrenzt
Integrität
Begrenzt
Verfügbarkeit
Keine
Ausnutzungswahrscheinlichkeit innerhalb von 30 Tagen
0.2%
Perzentil
12e
Quelle: FIRST.org, aktualisiert am 7. November 2026.
Zum Zeitpunkt des Abrufs waren keine offiziellen Patch-Informationen verfügbar; konsultieren Sie die offizielle Quelle.
Unsere eigene Einordnung und unser Kontext zu den obigen Quelldaten.
IACS-Radar-Einordnung
Unsere eigene Einordnung und unser Kontext zu dieser Schwachstelle — keine offizielle Quelle.
IACS-Radar-Prioritätswert
Basierend auf CVSS 5.4, EPSS 0.2%, industrielle Relevanz 25/100; angehoben wegen Relevanz für Internet-Exposition.
Kombiniert CVSS, EPSS, KEV-Status, industrielle Relevanz und Expositionsrelevanz — eine Ergänzung, kein Ersatz für die einzelnen Werte darunter und darüber.
Voraussetzungen für eine Ausnutzung
Operative Auswirkungen & Energierelevanz
Begrenzte Auswirkung auf die Verfügbarkeit; das Risiko liegt vor allem bei der Vertraulichkeit oder Integrität von Prozessdaten.
Keine starken energiesektorspezifischen Signale erkannt; allgemeine OT-/ICS-Relevanz.
Dieses Produkt verwendet Protokolle, die für die Analyse der Internet-Exposition relevant sind. Ein aus dem Internet erreichbarer Dienst ist nicht automatisch verwundbar.
Empfohlene defensive Maßnahmen
Industrieller Relevanzwert
Die Einstufung ist vorläufig; eine manuelle Überprüfung durch einen OT-Security-Analysten wird empfohlen.
Klassifiziert von IACS Radar-analysepijplijn (geautomatiseerd) am 8. November 2026.
IEC-62443-Zuordnung
Automatische IACS-Radar-Einordnung anhand der gemeldeten CWE-Schwächeklassifizierung; keine offizielle Zertifizierungsaussage.