Schwachstellen werden geladen…
Schwachstellen werden geladen…
CVE-2026-98499
In the Linux kernel, the following vulnerability has been resolved: HID: wacom: fix OOB read in wacom_wac_pen_serial_enforce() The 'wacom_wac_pen_serial_enforce()' function may calculate and pass an invalid offset to hid_field_extract(), resulting in memory reads at incorrect addresses -- possibly beyond the end of the report. If a field in the HID descriptor lists more usages than its Report Count actually reserves space for, the function's inner 'j' will walk past the end of the field: for (i = 0; i < report->maxfield; i++) { for (j = 0; j < report->field[i]->maxusage; j++) { ... value = hid_field_extract(hdev, raw_data + 1, offset + j * size, size); A descriptor listing 12288 usages against Report Count 1 has the loop extract the usage at index 12287 from bit offset 98296 -- about 12 KB past a 2-byte received report. The value is stored in wacom_wac->serial[0] and can reach userspace as an MSC_SERIAL event, making this an information disclosure. Clamp the loop to field->report_count, the number of value slots the report holds. Value slots past the last declared usage are still scanned; they reuse that usage (HID 1.11, 6.2.2.8). Verified on v6.12.105 with a UHID reproducer: a 2-byte report from such a descriptor trips KASAN before the patch and not after it.
Dieser Datensatz: Live-Anbindung— zuletzt abgerufen: 7. November 2026 um 01:04.
Hersteller
Produkt
Veröffentlicht
18. Oktober 2026
Zuletzt geändert
24. Oktober 2026
Direkt aus NVD, CISA oder vom Hersteller übernommen — teils auf Englisch, unverändert gegenüber der Quelle.
In the Linux kernel, the following vulnerability has been resolved: HID: wacom: fix OOB read in wacom_wac_pen_serial_enforce() The 'wacom_wac_pen_serial_enforce()' function may calculate and pass an invalid offset to hid_field_extract(), resulting in memory reads at incorrect addresses -- possibly beyond the end of the report. If a field in the HID descriptor lists more usages than its Report Count actually reserves space for, the function's inner 'j' will walk past the end of the field: for (i = 0; i < report->maxfield; i++) { for (j = 0; j < report->field[i]->maxusage; j++) { ... value = hid_field_extract(hdev, raw_data + 1, offset + j * size, size); A descriptor listing 12288 usages against Report Count 1 has the loop extract the usage at index 12287 from bit offset 98296 -- about 12 KB past a 2-byte received report. The value is stored in wacom_wac->serial[0] and can reach userspace as an MSC_SERIAL event, making this an information disclosure. Clamp the loop to field->report_count, the number of value slots the report holds. Value slots past the last declared usage are still scanned; they reuse that usage (HID 1.11, 6.2.2.8). Verified on v6.12.105 with a UHID reproducer: a 2-byte report from such a descriptor trips KASAN before the patch and not after it.
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H
Attack Vector
NETWORK
Privileges Required
NONE
User Interaction
NONE
Vertraulichkeit
Hoch
Integrität
Keine
Verfügbarkeit
Hoch
Ausnutzungswahrscheinlichkeit innerhalb von 30 Tagen
0.4%
Perzentil
33e
Quelle: FIRST.org, aktualisiert am 6. November 2026.
Zum Zeitpunkt des Abrufs waren keine offiziellen Patch-Informationen verfügbar; konsultieren Sie die offizielle Quelle.
Unsere eigene Einordnung und unser Kontext zu den obigen Quelldaten.
IACS-Radar-Einordnung
Unsere eigene Einordnung und unser Kontext zu dieser Schwachstelle — keine offizielle Quelle.
IACS-Radar-Prioritätswert
Basierend auf CVSS 8.1, EPSS 0.4%, industrielle Relevanz 35/100.
Kombiniert CVSS, EPSS, KEV-Status, industrielle Relevanz und Expositionsrelevanz — eine Ergänzung, kein Ersatz für die einzelnen Werte darunter und darüber.
Voraussetzungen für eine Ausnutzung
Operative Auswirkungen & Energierelevanz
Möglicher Verlust der Sicht auf oder der Kontrolle über den Prozess bei erfolgreicher Ausnutzung.
Keine starken energiesektorspezifischen Signale erkannt; allgemeine OT-/ICS-Relevanz.
Empfohlene defensive Maßnahmen
Industrieller Relevanzwert
Die Einstufung ist vorläufig; eine manuelle Überprüfung durch einen OT-Security-Analysten wird empfohlen.
Klassifiziert von IACS Radar-analysepijplijn (geautomatiseerd) am 7. November 2026.
IEC-62443-Zuordnung
Automatische IACS-Radar-Einordnung anhand der gemeldeten CWE-Schwächeklassifizierung; keine offizielle Zertifizierungsaussage.