Advisories specifically aimed at industrial control systems — from CISA ICS-CERT and directly from vendors (including Siemens, ABB, Schneider Electric, WAGO and Phoenix Contact) — including revision history (initial publication, Update A, Update B) and linked CVEs.
43
Found
Advisory data: live connection— last retrieved: 8 November 2026 at 10:21.
Filters
1 active43 advisories found
Risk evaluation
The firmware update package (WUP) is not signed entirely. The used password offers no additional security, it is just meant to protect from unintentional modifications of the WUP file. Thus only the integrity of the signed firmware part (rauc file) is protected against intended manipulation. An attacker could manipulate the WUP file in a way that additional files with potentially malicious content are added to the WUP file. In case an authorized user that issues a firmware update could be tricked into installing this manipulated WUP file onto the device, the potentially malicious files would also be copied and installed on to the device and executed with elevated privileges.
Mitigation summary
Execute FW-Update only as user 'admin'.
Revision history (2)
Initial publication — 9 March 2020
initial revision
Update A — 22 May 2025
Fix: version space, quotation mark
Published
9 March 2020
Last update
22 May 2025
Linked CVEs
Affected sectors
Risk evaluation
An attacker needs an authorized login on the device in order to exploit the herein mentioned vulnerabilities. The reported vulnerabilities allow a local attacker with valid login credentials who is able to create files on the device to change the devices settings, e.g. default gateway address, time server etc. and potentially execute code.
Mitigation summary
* Disable I/O-Check service. * Restrict network access to the device. * Do not directly connect the device to the internet. * Disable unused TCP/UDP-ports.
Revision history (2)
Initial publication — 9 March 2020
Initial revision.
Update A — 22 May 2025
Fix: version space, quotation mark
Published
20 May 2021
Last update
22 May 2025
Linked CVEs
Affected sectors
Risk evaluation
Multiple vulnerabilities were reported in CODESYS 2.3 Runtime. The CODESYS 2.3 Runtime is an essential component in several WAGO PLC's.
Mitigation summary
If an immediate firmware update is not possible, the WLAN on the unit can also be switched off as a precautionary measure.
Revision history (2)
Initial publication — 15 May 2021
Initial revision.
Update A — 22 May 2025
Fix: version space, added distribution, quotation mark
Risk evaluation
A Denial-of-Service Vulnerability was reported in CODESYS 2.3 Runtime. The CODESYS 2.3 Runtime is an essential component in several WAGO PLC's. All vulnerable PLCs are listed in chapter 'Affected Products'.
Mitigation summary
1. Use general security best practices to protect systems from local and network attacks. 2. Do not allow direct access to the device from untrusted networks. 3. Update to the latest firmware according to the table in chapter solutions. 4. Disable the CODESYS 2.3 port 2455.
Revision history (2)
Initial publication — 16 November 2021
initial revision
Update A — 22 May 2025
Fix: version space, added distribution, quotation mark
Published
5 January 2022
Last update
22 May 2025
Affected sectors
Risk evaluation
Apache Log4j is used for logging events in WAGO Smart Script in Version 4.2 and higher. Events logged by Log4j can contain JNDI references. An attacker who can control log messages or log message parameters can execute arbitrary code loaded from LDAP servers when message lookup substitution is enabled. Additionally, Log4j does not protect from self-referential lookups, which can lead to Denial of Service. UPDATE A1/2: Affected versions: CVE-2021-44228 and CVE-2021-45046: WAGO Smart Script >= Version 4.2 and < Version 4.8.1.3 CVE-2021-45105: WAGO Smart Script >= Version 4.2 and < Version 4.8.1.4 CVE-2021-44832 WAGO Smart Script >= Version 4.2 and < Version 4.8.1.5 END UPDATE A1/2
Mitigation summary
Do not use projects from untrusted sources. For further impact information and risk mitigation, see the recommendations of the Apache Foundation https://logging.apache.org/log4j/2.x/security.html Bundesamt für Sicherheit in der Informationstechnik (BSI) https://www.bsi.bund.de/DE/Service-Navi/Presse/Pressemitteilungen/Presse2021/211211_log4Shell_WarnstufeRot.html
Revision history (3)
Initial publication — 5 January 2022
Initial revision.
Update A — 9 February 2022
Update
Update B — 22 May 2025
Fix: added distribution, quotation mark
VDE-2022-002
WAGO: Vulnerable WIBU-SYSTEMS Codemeter installed through e!COCKPIT and WAGO-I/O-Pro
Risk evaluation
A vulnerability is reported in WIBU-SYSTEMS Codemeter. WIBU-SYSTEMS Codemeter is installed by default during e!COCKPIT and WAGO-I/O-Pro (CODESYS 2.3) installations. All currently existing e!COCKPIT installation bundles and WAGO-I/O-Pro (CODESYS 2.3) installation bundles are affected with vulnerable versions of WIBU-SYSTEMS Codemeter.
Mitigation summary
Mitigation Use general security best practices to protect systems from local and network attacks. Disable the container type 'Mass Storage' in CodeMeter via the Windows Registry.
Revision history (2)
Initial publication — 31 January 2022
Initial revision.
Update A — 22 May 2025
Fix: quotation mark
Risk evaluation
The Linux kernel starting from 5.8 has a flaw which can lead to privilege escalation for a local user. The kernel is used in several Versions of the FW of several WAGO products. All vulnerable PLCs are listed in chapter 'Affected Products'.
Mitigation summary
- Restrict network access to the device. - Use strong passwords - Do not directly connect the device to the internet - Disable unused TCP/UDP-ports
Revision history (2)
Initial publication — 6 April 2022
Initial revision.
Update A — 22 May 2025
Fix: quotation mark
Risk evaluation
The 'legal information' plugin of web-based-management contained a vulnerability which allowed execution of arbitrary commands with privileges of www user. UPDATE A 15.06.2023 : Removed PFC100 with FW23 as affected product and from solution PFC200 with FW23 is only affected on 750-821x/xxx-xxx Renamed "FW22 Patch 1" to "FW22 SP1" to match the versions of the download portal
Mitigation summary
As general security measures strongly WAGO recommends: Use general security best practices to protect systems from local and network attacks. Do not allow direct access to the device from untrusted networks. Update to the latest firmware according to the table in chapter solutions. Industrial control systems (ICS) should not be directly accessible from the Internet, but should be protected by consistently applying the defense-in-depth strategy. The BSI provides general information on securing ICS in the ICS Compendium (https://www.bsi.bund.de/SharedDocs/Downloads/EN/BSI/ICS/ICS-Security_compendium.pdf).
Revision history (2)
Initial publication — 15 May 2023
Initial revision.
Update A — 22 May 2025
Fix: quotation mark
VDE-2023-026
WAGO: Multiple products prone to multiple vulnerabilities in e!Runtime / CODESYS V3 Runtime
Published
31 July 2023
Last update
22 May 2025
Linked CVEs
Affected sectors
Risk evaluation
Multiple WAGO devices are prone to vulnerabilites in the used CODESYS V3 framework.
Mitigation summary
Vulnerabilities of CODESYS Advisory 2023-02:• Please make sure that the 'port authentication' option in the web-based management is activated. In this way none of the vulnerabilities can be exploited by unauthenticated users.• Please change the default admin password. Vulnerability of CODESYS Advisory 2023-03:• This vulnerability exists in the CODESYS programming service which is needed for commission only. Deactivate the CODESYS programming port in the web-based management if you do not need the service. In addition to the mitigation hints CODESYS GmbH recommends the following general defense measures to reduce the risk of exploits: Use controllers and devices only in a protected environment to minimize network exposure and ensure they are not accessible from outside. Use firewalls to protect and separate the control system network from other networks. Use VPN (Virtual Private Networks) tunnels if remote access is required. Activate and apply user management and password features. Use encrypted communication links. Limit the access to both development and control system by physical means, operating system features, etc. Protect both development and control system by using up to date virus detection solutions. For further impact information and risk mitigation, please refer to the official CODESYS Advisory Website at https://www.codesys.com/security/security-reports.html
Revision history (2)
Initial publication — 31 July 2023
Initial revision.
Update A — 22 May 2025
Fix: quotation mark
Published
18 November 2024
Last update
22 May 2025
Linked CVEs
Affected sectors
Risk evaluation
Nozomi reported eight vulnerabilities to WAGO affecting different firmwares installed on several devices.
Mitigation summary
Update to Firmware 4.6.1 (FW28) or for CC100 devices to 4.6.3 (FW28). For G1 devices update to Firmware 3.10.11 (FW22 Patch 2). For the latest Custom Firmware, please contact the WAGO support.
Revision history (4)
Initial publication — 18 November 2024
Initial document.
Update A — 30 January 2025
Added known mitigations as remediation. Added the Custom Firmware to the product branch. Added firmware 3.10.11 (Firmware 22 Patch 2) to the fixed products. This version was in revision 1 listed as vulnerable.
Update B — 12 February 2025
Fix: corrected self-reference, fixed version
Update C — 22 May 2025
Fix: quotation mark
Published
29 June 2021
Last update
14 May 2025
Affected sectors
Risk evaluation
Multiple vulnerabilities in the WAGO I/O-Check Service were reported.
Mitigation summary
- Disable I/O-Check service - Restrict network access to the device. - Do not directly connect the device to the internet.
Revision history (4)
Initial publication — 29 June 2021
Initial revision.
Update A — 6 November 2024
Fix: added self-reference
Update B — 12 February 2025
Fix: corrected self-reference, fixed version
Update C — 10 April 2025
Fixed csaf publisher information
Risk evaluation
The following firmware versions installed on several devices are are vulnerable due to a vulnerability in CODESYS Control.
Mitigation summary
The vulnerability is only exploitable if the an attacker has successfully logged in with according user rights. To prevent attackers from exploiting the vulnerability it is recommend to change the standard password in the web based management.
Revision history (3)
Initial publication — 4 February 2025
Initial release.
Update A — 19 February 2025
Update: fixed typo in Vendor fix, fixed version
Update B — 14 May 2025
Fix: added distribution
Risk evaluation
The communication between e!Cockpit and the programmable logic controller is not encrypted. The broken cryptographic algorithm allows an attacker to decode the password for the e!Cockpit communication and with this to manipulate the application. The password used by e!Cockpit for authentication against the PLC is encrypted with a hard-coded key. An attacker is able to decrypt the password by listening to the network traffic.
Mitigation summary
* Follow the instructions in WAGO's handbook Cyber Security for Controller * Restrict network access to the device. * Do not directly connect the device to the internet * Use an encrypted VPN connection to the device * Disable unused TCP/UDP-ports Typically the e!Cockpit communication is only needed during commissioning of the programmable logic controller and not during normal operations. WAGO highly recommends disabling the TCP Port 11740 and UDP Port 1740 after commissioning or using an encrypted VPN connection to the device.
Revision history (3)
Initial publication — 9 March 2020
initial revision
Update A — 10 April 2025
Fixed namespace URL
Update B — 14 May 2025
Fix: added distribution
VDE-2020-028
WAGO: Authentication Bypass Vulnerability in WAGO 750-36X and WAGO 750-8XX Version <= FW03
Risk evaluation
The Web-Based Management (WBM) of WAGOs programmable logic controller (PLC) is typically used for administration, commissioning and updates. With special crafted requests it is possible to change some special parameters without authentication.
Mitigation summary
* Restrict network access to the device. * Do not directly connect the device to the internet. * Disable unused TCP/UDP ports. * Disable web-based management ports 80/443 after the configuration phase
Revision history (3)
Initial publication — 30 September 2020
initial revision
Update A — 10 April 2025
Fixed csaf reference URL
Update B — 14 May 2025
Fix: added distribution
VDE-2020-029
WAGO: XSS vulnerability in Web-UI in WAGO 750-88X and WAGO 750-89X
Risk evaluation
The Web-Based Management (WBM) of WAGOs programmable logic controller (PLC) is typically used for administration, commissioning and updates. The SNMP configuration page of the device is vulnerable for a persistent XSS (Cross-Site Scripting) attack.
Mitigation summary
* Restrict network access to the device. * Use strong passwords * Do not directly connect the device to the internet * Disable unused TCP/UDP-ports
Revision history (3)
Initial publication — 30 September 2020
initial revision
Update A — 10 April 2025
Fixed csaf reference URL
Update B — 14 May 2025
Fix: added distribution
Risk evaluation
The Fraunhofer Institute discovered a vulnerability in the Profinet IO Coupler 0750-0375 during fuzzing tests. These tests revealed weaknesses in the validation and processing of incoming data packets across various protocols and services.
Mitigation summary
Update to firmware version 02.10.01 (12).
Revision history (1)
Initial publication — 11 March 2025
Initial release.
Risk evaluation
Nozomi Networks reported a vulnerability in the pfc firmware sdk-G2 of libwagosnmp. The WAGO pfc-firmware-sdk-G2 is a software development kit designed for WAGO PFC devices which developers to build and customize the firmware.
Mitigation summary
Update to Firmware 04.07.01 (FW29) or Firmware 03.10.11 (FW22 Patch 2). For the latest Custom Firmware, please contact the WAGO support.
Revision history (1)
Initial publication — 5 March 2025
Initial release.
Risk evaluation
Several WAGO Firmwares are vulnerable, due to an incorrect calculation of the buffer size in the CODESYS OPC UA STACK. This can lead to a crash of the runtime of the following firmware versions installed on several devices.
Mitigation summary
The incorrect calculation of the buffer size can be avoided if the maximum supported array length of the OPC UA stack of the CODESYS Control runtime system is limited to a value of 10129639 (Stack.MaxArrayLenth=10129639) or less. This can be achieved by adding the following setting in the runtime configuration under the following path: /etc/codesys3.d/codesyscotrol.cfg
Revision history (1)
Initial publication — 4 February 2025
Initial release.