Advisories specifically aimed at industrial control systems — from CISA ICS-CERT and directly from vendors (including Siemens, ABB, Schneider Electric, WAGO and Phoenix Contact) — including revision history (initial publication, Update A, Update B) and linked CVEs.
1
Found
Advisory data: live connection— last retrieved: 20 November 2026 at 20:17.
Filters
1 active1 advisories found
Published
12 November 2026
Last update
12 November 2026
Linked CVEs
Affected sectors
Risk evaluation
An update is available that resolves the publicly reported vulnerabilities in the PHP and OpenSSL components in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could insert and run arbitrary code. An attacker who successfully exploited the OpenSSL vulnerability (CVE-2026-35189) could cause a denial of service of the affected products.
Mitigation summary
The vulnerabilities are fixed with the following product version: 5.6.2. ABB recommends that customers apply the update at earliest convenience. Physical access to the ACF5000 LCS/CCUS for the update procedure is strongly recommended. The ACF5000 LCS will re-boot during the update procedure and the gas measurement will be interrupted. ABB advises not to perform the update if - the ACF5000 LCS/CCUS is performing critical measurements, and the interruption of the measurement is not acceptable. - the customer does not feel confident in performing the update themselves. Update procedure: 1. Download the latest version of the SMT for ACF5000 software using the ABB Library. Please refer to the reference section for the download link (SMT for ACF5000 software). 2. Run SMT and connect the ACF5000 LCS/CCUS via Ethernet cable to the computer running SMT. 3. Follow the steps outlined in the SMT user manual. ABB recommends performing the update step-by-step (Save configuration data, Load new software, Load configuration data). Please refer to the reference section for the download link (SMT user manual). 4. Verify that all connections to DCS and/or Data Acquisition Handling systems are established and correct. 5. In case the remote connection (AO-HMI for ACF5000) was used, it needs to be updated to match the ACF5000 LCS/CCUS software version. Please refer to the reference section for the download link (AO-HMI for ACF5000). In case an update is not possible or the customer prefers the update to be performed by a service technician, ABB strongly recommends setting the web server of the ACF5000 LCS/CCUS to be available on interface “X8” only, as described in section “Workarounds”. The ACF5000 LCS/CCUS is designed to be operated in an isolated network segment as described in section “Mitigating factors”.
Revision history (1)
Initial publication — 12 November 2026
Initial version.