VDE-2021-011

TRUMPF Laser GmbH: TruControl 2.14.0 to 3.14.0 affected by recent sudo vulnerability

TRUMPF — redpowerDirect

TRUMPF PSIRThigh

Published

22 March 2021

Last update

2 February 2026

Linked CVEs

Affected sectors

Risk evaluation

TruControl laser control software from versions 2.14.0 to 3.14.0 use sudo versions affected by CVE-2021-3156. The affected sudo has a heap-based buffer overflow, allowing privilege escalation to root via "sudoedit -s" and a command-line argument that ends with a single backslash character.

Mitigation summary

- Update to TruControl version 3.16.0 or higher or - Please contact your service partner (service.tls@trumpf.com) for instructions on how to retrieve the patch

Revision history (4)
  1. Initial publication — 22 March 2021

    initial revision

  2. Update A — 10 April 2025

    Fixed csaf reference URL and publisher information.

  3. Update B — 14 May 2025

    Fix: added distribution

  4. Update C — 2 February 2026

    Fix: CSAF Document Alias had the wrong VDE-ID, changed revision versioning scheme to semver

Official source: TRUMPF PSIRT