CISA + vendors
ICS Advisories
Advisories specifically aimed at industrial control systems — from CISA ICS-CERT and directly from vendors (including Siemens, ABB, Schneider Electric, WAGO and Phoenix Contact) — including revision history (initial publication, Update A, Update B) and linked CVEs.
1
Found
Advisory data: live connection— last retrieved: 7 November 2026 at 02:35.
Filters
1 active1 advisories found
VDE-2021-033
TRUMPF Laser GmbH: multiple products prone to codesys runtime vulnerabilities
Published
12 August 2021
Last update
12 August 2021
Linked CVEs
Affected sectors
Risk evaluation
The TruControl laser control software (versions 1.04 to 3.0.0) uses CODESYS runtime versions affected by multiple CVEs: **CVE list:** - CVE-2021-29242 - CVE-2021-29241 - CVE-2019-5105 - CVE-2020-7052 - CVE-2019-9012 - CVE-2019-9010 - CVE-2019-9009 - CVE-2018-10612 In addition to the CVEs listed above, the affected products are also vulnerable to the following issues without a CVE ID: --- ### **CODESYS Advisory 2018-07** A crafted communication request may cause an access violation in the affected CODESYS products and may result in a denial-of-service condition. - **CVSS v3.0 base score:** 6.5 - **CVSS v3.0 vector:** `CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H` 🔗 [Link to advisory](https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=12928&token=6d1dcea05a15aeef7ad48eadc64c8eca5d4f07b2&download=) --- ### **CODESYS Advisory 2018-04** The CODESYS runtime system allows access to files outside the restricted working directory of the controller by online services. - **CVSS v3.0 base score:** 9.9 - **CVSS v3.0 vector:** `CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H` 🔗 [Link to advisory](https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=12925&token=50e7240fa947ea215311e3db441f82152f1109b6&download=) --- ### **CODESYS Advisory 2017-03** A crafted request may cause an access violation in the affected CODESYS products and may result in a denial-of-service condition. - **CVSS v3.0 base score:** 7.5 - **CVSS v3.0 vector:** `CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H` 🔗 [Link to advisory](https://customers.codesys.com/index.php?eID=dumpFile&t=f&f=12912&token=2f23e7f047c2768dd06fdf072de49a7ba1fe9687&download=)
Mitigation summary
- We highly recommend updating to TruControl version 3.16.0 or higher as soon as possible - Please contact your service partner (service.tls@trumpf.com) for immediate instructions on how to retrieve the update
Revision history (1)
Initial publication — 12 August 2021