Skip to content
IACS RadarIndustrial Cyber Exposure & Intelligence

CISA + vendors

ICS Advisories

Advisories specifically aimed at industrial control systems — from CISA ICS-CERT and directly from vendors (including Siemens, ABB, Schneider Electric, WAGO and Phoenix Contact) — including revision history (initial publication, Update A, Update B) and linked CVEs.

1

Found

Advisory data: live connection— last retrieved: 7 November 2026 at 01:04.

Filters

1 active
Reset filters

1 advisories found

VDE-2025-064

Phoenix Contact: Products utilizing WIBU-SYSTEMS CodeMeter Runtime Windows Installer have a privilege escalation

Phoenix Contact — CodeMeter Runtime licensed Software

Phoenix Contact PSIRThigh

Published

9 September 2025

Last update

9 September 2025

Linked CVEs

Affected sectors

Control centres

Risk evaluation

A local privilege escalation vulnerability in Phoenix Contact products utilizing WIBU-SYSTEMS CodeMeter Runtime allows users to gain admin rights on freshly installed systems. The CodeMeter Control Center starts with elevated privileges and retains them until restarted, enabling unauthorized access to admin tools like cmd.exe.

Mitigation summary

PHOENIX CONTACT strongly recommends affected users to upgrade to CodeMeter V8.30a, which fixes these vulnerabilities. WIBU-SYSTEMS has already published this update for CodeMeter on their homepage. Since this current version of CodeMeter V8.30a has not yet been incorporated into Phoenix Contact products, we strongly recommend to download and install the current CodeMeter version directly from the WIBU-SYSTEMS homepage. Additional Recommendations: Regularly check the product's official webpage for updated release versions that support CodeMeter V8.30a. Update the Activation Wizard to version 1.8 as soon as it becomes available on the product's download page.

Revision history (1)
  1. Initial publication — 9 September 2025

    Initial

Official source: Phoenix Contact PSIRT