Risk evaluation
The Linux kernel used by the affected egOS releases contains a use-after-free vulnerability in the IPv4 TCP connection-handling path. An unauthenticated remote attacker can send specially crafted IPv4 TCP packets containing IP options to a listening service and race retransmitted connection requests against connection establishment or teardown. Successful exploitation may disclose or corrupt kernel memory, crash the device, or potentially allow arbitrary code execution with kernel privileges.
Mitigation summary
- Do not expose egOS management interfaces or other TCP services directly to the internet or other untrusted networks. - Restrict inbound TCP access to trusted systems using network segmentation, firewall rules, or a VPN. - At a trusted upstream firewall, block inbound IPv4 TCP packets that contain IPv4 header options. Test this measure against operational requirements before deployment because it may disrupt traffic that legitimately uses IPv4 options. Standard TCP options are not affected. - Disable unused TCP services. If Multipath TCP is enabled, disable it where operationally possible. Disabling Multipath TCP reduces exposure to demonstrated remote code execution paths but does not fully mitigate the vulnerability. - Monitor affected devices for unexpected restarts, kernel faults, and anomalous inbound TCP traffic containing IPv4 options.
Revision history (1)
Initial publication — 16 November 2026