CISA + vendors
ICS Advisories
Advisories specifically aimed at industrial control systems — from CISA ICS-CERT and directly from vendors (including Siemens, ABB, Schneider Electric, WAGO and Phoenix Contact) — including revision history (initial publication, Update A, Update B) and linked CVEs.
1
Found
Advisory data: live connection— last retrieved: 20 November 2026 at 19:46.
Filters
1 active1 advisories found
Risk evaluation
An integer overflow vulnerability exists in the open-source repository sick_scan_xd (https://github.com/SICKAG/sick_scan_xd), a ROS 2 driver library and software development kit for SICK LiDAR and RADAR devices. A specially crafted network packet could cause an integer overflow during packet size validation, potentially bypassing boundary checks and resulting in out-of-bounds reads. If exploited, this vulnerability could affect the availability of applications using the affected library. SICK recommends applying the defined remediation for this vulnerability.
Mitigation summary
Users are recommended to upgrade to version 3.10.0.
Revision history (1)
Initial publication — 18 November 2026
Initial version