CVE-2017-5715
Systems with microprocessors utilizing speculative execution and indirect branch prediction may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis.
This record: live connection— last retrieved: 7 November 2026 at 00:32.
Vendor
Products
AXC 3051, AXC F 2152, BL2 BPC 1000, BL2 BPC 2000, BL2 BPC 7000, BL2 PPC 1000 and 6 more
up to version vers:all/*
Published
4 January 2018
Last modified
17 June 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
Systems with microprocessors utilizing speculative execution and indirect branch prediction may allow unauthorized disclosure of information to an attacker with local user access via a side-channel analysis.
CVSS:3.1/AV:L/AC:H/PR:L/UI:N/S:C/C:H/I:N/A:N
Attack vector
LOCAL
Privileges required
LOW
User interaction
NONE
Confidentiality
High
Integrity
None
Availability
None
Probability of exploitation within 30 days
73.2%
Percentile
99e
Source: FIRST.org, updated on 6 November 2026.
On Industrial PCs and HMIs that operate with user installable or upgradable operating systems (mainly Windows) the latest version or update may be installed if required in the use case. As the update may have a performance impact, the application should be tested accordingly.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 5.6, EPSS 73.2%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Limited impact on availability; the risk lies mainly with confidentiality or integrity of process data.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Phoenix Contact" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.