Loading vulnerabilities…
Loading vulnerabilities…
CVE-2018-16059
Endress+Hauser WirelessHART Fieldgate SWG70 3.x devices allow Directory Traversal via the fcgi-bin/wgsetcgi filename parameter.
This record: live connection— last retrieved: 7 November 2026 at 03:37.
Vendor
Published
8 September 2018
Last modified
17 June 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
Endress+Hauser WirelessHART Fieldgate SWG70 3.x devices allow Directory Traversal via the fcgi-bin/wgsetcgi filename parameter.
CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Confidentiality
Limited
Integrity
None
Availability
None
Probability of exploitation within 30 days
29.8%
Percentile
98e
Source: FIRST.org, updated on 6 November 2026.
A Firmware (version see table below), which solves the problem, is available. Please contact your support representative for this particular firmware package and update the corresponding product. | Product ID | Version | Bus-Interface of Device | |-----------------|----------|-------------------------| | WHA-GW-*-ETH | 03.00.08 | Modbus | | WHA-GW-*-ETH.EIP | 02.00.01 | Ethernet/IP |
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 5.3, EPSS 29.8%, industrial relevance 40/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Limited impact on availability; the risk lies mainly with confidentiality or integrity of process data.
No strong energy-sector-specific signals recognised; general OT/ICS relevance.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.