CVE-2020-9403
In PACTware before 4.1 SP6 and 5.x before 5.0.5.31, passwords are stored in a recoverable format, and may be retrieved by any user with access to the PACTware workstation.
This record: live connection— last retrieved: 7 November 2026 at 03:37.
Vendor
Published
11 August 2020
Last modified
17 June 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
In PACTware before 4.1 SP6 and 5.x before 5.0.5.31, passwords are stored in a recoverable format, and may be retrieved by any user with access to the PACTware workstation.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N
Attack vector
LOCAL
Privileges required
LOW
User interaction
NONE
Confidentiality
High
Integrity
None
Availability
None
Probability of exploitation within 30 days
0.3%
Percentile
21e
Source: FIRST.org, updated on 6 November 2026.
PACTware will protect the manipulation of stored passwords by using a salted mechanism of password encryption with an additional SHA256 hash. This will be fixed in following versions (and higher): * PACTware 5.0.5.31 * PACTware 4.1 SP6 Overview about version history: https://pactware.com/de/service You can protect yourself against manipulation by restricting the access to the PC where PACTware is installed. In case of not known passwords it can be reset by reinstallation of PACTware (all PACTware versions).
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 5.5, EPSS 0.3%, industrial relevance 40/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Limited impact on availability; the risk lies mainly with confidentiality or integrity of process data.
No strong energy-sector-specific signals recognised; general OT/ICS relevance.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.