Loading vulnerabilities…
Loading vulnerabilities…
CVE-2021-47002
In the Linux kernel, the following vulnerability has been resolved: SUNRPC: Fix null pointer dereference in svc_rqst_free() When alloc_pages_node() returns null in svc_rqst_alloc(), the null rq_scratch_page pointer will be dereferenced when calling put_page() in svc_rqst_free(). Fix it by adding a null check. Addresses-Coverity: ("Dereference after null check")
This record: live connection— last retrieved: 6 November 2026 at 23:32.
Vendor
Published
28 February 2024
Last modified
14 October 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
In the Linux kernel, the following vulnerability has been resolved: SUNRPC: Fix null pointer dereference in svc_rqst_free() When alloc_pages_node() returns null in svc_rqst_alloc(), the null rq_scratch_page pointer will be dereferenced when calling put_page() in svc_rqst_free(). Fix it by adding a null check. Addresses-Coverity: ("Dereference after null check")
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Attack vector
LOCAL
Privileges required
LOW
User interaction
NONE
Confidentiality
None
Integrity
None
Availability
High
Probability of exploitation within 30 days
0.2%
Percentile
15e
Source: FIRST.org, updated on 6 November 2026.
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 5.5, EPSS 0.2%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Siemens" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 6 November 2026.
IEC 62443 mapping