Loading vulnerabilities…
Loading vulnerabilities…
CVE-2022-3073
Quanos "SCHEMA ST4" example web templates in version Bootstrap 2019 v2/2021 v1/2022 v1/2022 SP1 v1 or below are prone to JavaScript injection allowing a remote attacker to hijack existing sessions to e.g. other web services in the same environment or execute scripts in the users browser environment. The affected script is '*-schema.js'.
This record: live connection— last retrieved: 7 November 2026 at 02:35.
Vendor
Products
19 IOT MD01 LAN H4 S0011, FP IOT, IOT-GW30, IOT-GW30-4G-EU, UC20-WL2000-AC, UC20-WL2000-IOT
up to version vers:all/*
Published
14 December 2022
Last modified
17 June 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
Quanos "SCHEMA ST4" example web templates in version Bootstrap 2019 v2/2021 v1/2022 v1/2022 SP1 v1 or below are prone to JavaScript injection allowing a remote attacker to hijack existing sessions to e.g. other web services in the same environment or execute scripts in the users browser environment. The affected script is '*-schema.js'.
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
Attack vector
NETWORK
Privileges required
NONE
User interaction
REQUIRED
Confidentiality
Limited
Integrity
Limited
Availability
None
Probability of exploitation within 30 days
0.5%
Percentile
42e
Source: FIRST.org, updated on 6 November 2026.
If the remediation cannot be implemented in a timely manner, Weidmueller strongly recommends that the authenticated user logged in to the product does not click on links from external sources.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 6.1, EPSS 0.5%, industrial relevance 40/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Limited impact on availability; the risk lies mainly with confidentiality or integrity of process data.
No strong energy-sector-specific signals recognised; general OT/ICS relevance.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping