CVE-2023-31468
An issue was discovered in Inosoft VisiWin 7 through 2022-2.1 (Runtime RT7.3 RC3 20221209.5). The "%PROGRAMFILES(X86)%\INOSOFT GmbH" folder has weak permissions for Everyone, allowing an attacker to insert a Trojan horse file that runs as SYSTEM. 2024-1 is a fixed version.
This record: live connection— last retrieved: 7 November 2026 at 03:37.
Vendor
Published
11 September 2023
Last modified
17 June 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
An issue was discovered in Inosoft VisiWin 7 through 2022-2.1 (Runtime RT7.3 RC3 20221209.5). The "%PROGRAMFILES(X86)%\INOSOFT GmbH" folder has weak permissions for Everyone, allowing an attacker to insert a Trojan horse file that runs as SYSTEM. 2024-1 is a fixed version.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack vector
LOCAL
Privileges required
LOW
User interaction
NONE
Confidentiality
High
Integrity
High
Availability
High
Probability of exploitation within 30 days
1.0%
Percentile
62e
Source: FIRST.org, updated on 6 November 2026.
Only use this tool in a protected and controlled environment to minimize network impact and to ensure that the tool is inaccessable from outside. In addition, the use of firewalls is recommended to reduce the attack surface, specially to the internet and the internal business network.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 7.8, EPSS 1.0%, industrial relevance 40/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
No strong energy-sector-specific signals recognised; general OT/ICS relevance.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.