Loading vulnerabilities…
Loading vulnerabilities…
CVE-2023-47360
Videolan VLC prior to version 3.0.20 contains an Integer underflow that leads to an incorrect packet length.
This record: live connection— last retrieved: 24 September 2026 at 05:11.
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
Videolan VLC prior to version 3.0.20 contains an Integer underflow that leads to an incorrect packet length.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Confidentiality
None
Integrity
None
Availability
High
Probability of exploitation within 30 days
0.9%
Percentile
59e
Source: FIRST.org, updated on 23 September 2026.
• Air-gapped environments only: Camera Connect is deployed in completely isolated environments lacking any network connectivity or internet access. • No exposure to MMS streams: The vulnerability depends on processing crafted MMS streams, which cannot originate from external or internal network sources when the system is air-gapped. • Elimination of remote attack surface: Without any method for an attacker to deliver malicious media inputs, the vulnerability cannot be triggered remotely. • Strong reduction in exploitation risk: The combined absence of external media ingestion and unavailable network paths effectively neutralizes the integer underflow exploit, significantly reducing the likelihood of both denial-of-service and memory corruption scenarios.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 7.5, EPSS 0.9%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "ABB" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 24 September 2026.
IEC 62443 mapping