CVE-2024-10083
CWE-20: Improper Input Validation vulnerability exists that could cause denial of service of engineering workstation when specific driver interface is invoked locally by an authenticated user with crafted input.
This record: live connection— last retrieved: 7 November 2026 at 14:52.
Vendor
Products
EcoStruxure Control Expert, EcoStruxure™ Process Expert, EcoStruxure™ Process Expert for AVEVA System Platform, OPC Factory Server
up to version vers:all/*
Published
13 February 2025
Last modified
17 June 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
CWE-20: Improper Input Validation vulnerability exists that could cause denial of service of engineering workstation when specific driver interface is invoked locally by an authenticated user with crafted input.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Attack vector
LOCAL
Privileges required
LOW
User interaction
NONE
Confidentiality
None
Integrity
None
Availability
High
Probability of exploitation within 30 days
0.2%
Percentile
4e
Source: FIRST.org, updated on 6 November 2026.
For customers requiring the use of Uni-Telway driver, Schneider Electric recommends using following mitigations to reduce the risk of exploit:• McAfee Application and Change Control software for application control. Refer to the Cybersecurity Application Note available https://www.se.com/ww/en/download/document/EIO0000004778/ • Follow workstation, network and site-hardening guidelines in the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/ww/en/download/document/7EN52-0390/) document. For customers not requiring the use of Uni-Telway driver, Schneider Electric recommends uninstalling the driver. Version 16.2 of EcoStruxureTM Control Expert, version 2025 of EcoStruxureTM Process Expert, version 2025 of EcoStruxureTM Process Expert for AVEVA System Platform, and version 3.63SP3 of OPC Factory Server do not include Uni-Telway driver by default anymore. This vulnerability is only affecting customers who have installed Uni-Telway driver.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 5.5, EPSS 0.2%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Schneider Electric" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.