Loading vulnerabilities…
Loading vulnerabilities…
CVE-2024-23337
jq is a command-line JSON processor. In versions up to and including 1.7.1, an integer overflow arises when assigning value using an index of 2147483647, the signed integer limit. This causes a denial of service. Commit de21386681c0df0104a99d9d09db23a9b2a78b1e contains a patch for the issue.
This record: live connection— last retrieved: 7 November 2026 at 01:04.
Vendor
Published
21 May 2025
Last modified
17 June 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
jq is a command-line JSON processor. In versions up to and including 1.7.1, an integer overflow arises when assigning value using an index of 2147483647, the signed integer limit. This causes a denial of service. Commit de21386681c0df0104a99d9d09db23a9b2a78b1e contains a patch for the issue.
CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:L
Attack vector
NETWORK
Privileges required
NONE
User interaction
REQUIRED
Confidentiality
None
Integrity
None
Availability
Limited
Probability of exploitation within 30 days
0.5%
Percentile
40e
Source: FIRST.org, updated on 6 November 2026.
Phoenix Contact strongly recommends upgrading affected mGuard devices to firmware version 1.8.1 or higher which fixes this vulnerability.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 4.3, EPSS 0.5%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Limited impact on availability; the risk lies mainly with confidentiality or integrity of process data.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Phoenix Contact" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.