Loading vulnerabilities…
Loading vulnerabilities…
CVE-2024-36922
In the Linux kernel, the following vulnerability has been resolved: wifi: iwlwifi: read txq->read_ptr under lock If we read txq->read_ptr without lock, we can read the same value twice, then obtain the lock, and reclaim from there to two different places, but crucially reclaim the same entry twice, resulting in the WARN_ONCE() a little later. Fix that by reading txq->read_ptr under lock.
This record: live connection— last retrieved: 7 November 2026 at 00:32.
Vendor
Published
30 May 2024
Last modified
15 October 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
In the Linux kernel, the following vulnerability has been resolved: wifi: iwlwifi: read txq->read_ptr under lock If we read txq->read_ptr without lock, we can read the same value twice, then obtain the lock, and reclaim from there to two different places, but crucially reclaim the same entry twice, resulting in the WARN_ONCE() a little later. Fix that by reading txq->read_ptr under lock.
CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Confidentiality
High
Integrity
High
Availability
High
Probability of exploitation within 30 days
0.3%
Percentile
28e
Source: FIRST.org, updated on 6 November 2026.
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 8.8, EPSS 0.3%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Siemens" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.