CVE-2024-41975
An unauthenticated remote attacker can gain limited information of the PLC network but the user management of the PLCs prevents the actual access to the PLCs.
This record: live connection— last retrieved: 24 September 2026 at 05:13.
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
An unauthenticated remote attacker can gain limited information of the PLC network but the user management of the PLCs prevents the actual access to the PLCs.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Confidentiality
Limited
Integrity
None
Availability
None
Probability of exploitation within 30 days
0.4%
Percentile
38e
Source: FIRST.org, updated on 23 September 2026.
If remote access is not required, check the "LocalAddress" setting in the [CmpGwCommDrvTcp] section of the Gateway's configuration file as follows (restart of gateway required in case of changes): [CmpGwCommDrvTcp] LocalAddress=127.0.0.1 ; allow access only from the local computer The gateway configuration file can be located at (example for Automation Builder 2.8): %ProgramFiles%\ABB\AB2.8\AutomationBuilder\GatewayPLC\Gateway.cfg Starting with Automation Builder version 2.9.0 the vulnerability is closed by setting the default for the gateway to local access. Automation Builder 2.9.0 is available for download from the related download site. https://www.abb.com/global/en/areas/motion/digital-tools/automation-builder/software-download
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 5.3, EPSS 0.4%, industrial relevance 75/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Limited impact on availability; the risk lies mainly with confidentiality or integrity of process data.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Productbeschrijving komt overeen met de categorie "PLC", een typisch OT/ICS-componenttype. Vendor "ABB" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Automatically classified as industrially relevant based on CISA/NVD signals (see reasons).
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 24 September 2026.