Loading vulnerabilities…
Loading vulnerabilities…
CVE-2025-11043
An Improper Certificate Validation vulnerability in the OPC-UA client and ANSL over TLS client used in Automation Studio versions before 6.5 could allow an unauthenticated attacker on the network to position themselves to intercept and interfere with data exchanges.
This record: live connection— last retrieved: 24 September 2026 at 05:14.
Published
19 January 2026
Last modified
17 June 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
An Improper Certificate Validation vulnerability in the OPC-UA client and ANSL over TLS client used in Automation Studio versions before 6.5 could allow an unauthenticated attacker on the network to position themselves to intercept and interfere with data exchanges.
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:N
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Confidentiality
High
Integrity
High
Availability
None
Probability of exploitation within 30 days
0.2%
Percentile
14e
Source: FIRST.org, updated on 23 September 2026.
The problem is corrected in the following product versions: B&R Automation Studio version 6.5 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is de-scribed in the user manual.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 7.4, EPSS 0.2%, industrial relevance 80/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Limited impact on availability; the risk lies mainly with confidentiality or integrity of process data.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Productbeschrijving komt overeen met de categorie "opc-server", een typisch OT/ICS-componenttype. Vendor "B&R Industrial Automation GmbH" is a known supplier of equipment for the energy sector. Description mentions industrial protocol: opc-ua.
Recommended defensive measures
Industrial relevance score
Automatically classified as industrially relevant based on CISA/NVD signals (see reasons).
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 24 September 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.