Loading vulnerabilities…
Loading vulnerabilities…
CVE-2025-11044
An Allocation of Resources Without Limits or Throttling vulnerability in the ANSL-Server component of B&R Automation Runtime versions prior to 6.5 and prior to R4.93 could be exploited by an unauthenti-cated attacker on the network to win a race condition, resulting in permanent denial-of-service (DoS) conditions on affected devices.
This record: live connection— last retrieved: 24 September 2026 at 05:11.
Published
19 January 2026
Last modified
17 June 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
An Allocation of Resources Without Limits or Throttling vulnerability in the ANSL-Server component of B&R Automation Runtime versions prior to 6.5 and prior to R4.93 could be exploited by an unauthenti-cated attacker on the network to win a race condition, resulting in permanent denial-of-service (DoS) conditions on affected devices.
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:C/C:N/I:N/A:H
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Confidentiality
None
Integrity
None
Availability
High
Probability of exploitation within 30 days
0.4%
Percentile
31e
Source: FIRST.org, updated on 23 September 2026.
The problem is corrected in the following product versions: - Automation Runtime 6 versions >= 6.5 - Automation Runtime 4 versions >= R4.93 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 6.8, EPSS 0.4%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "B&R Industrial Automation GmbH" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 24 September 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.