CVE-2025-11412
A vulnerability has been found in GNU Binutils 2.45. This impacts the function bfd_elf_gc_record_vtentry of the file bfd/elflink.c of the component Linker. The manipulation leads to out-of-bounds read. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. The identifier of the patch is 047435dd988a3975d40c6626a8f739a0b2e154bc. To fix this issue, it is recommended to deploy a patch.
This record: live connection— last retrieved: 24 September 2026 at 05:14.
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
A vulnerability has been found in GNU Binutils 2.45. This impacts the function bfd_elf_gc_record_vtentry of the file bfd/elflink.c of the component Linker. The manipulation leads to out-of-bounds read. Local access is required to approach this attack. The exploit has been disclosed to the public and may be used. The identifier of the patch is 047435dd988a3975d40c6626a8f739a0b2e154bc. To fix this issue, it is recommended to deploy a patch.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L
Attack vector
LOCAL
Privileges required
LOW
User interaction
NONE
Confidentiality
None
Integrity
None
Availability
Limited
Probability of exploitation within 30 days
0.2%
Percentile
11e
Source: FIRST.org, updated on 23 September 2026.
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 3.3, EPSS 0.2%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Limited impact on availability; the risk lies mainly with confidentiality or integrity of process data.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Siemens" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 24 September 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.