Loading vulnerabilities…
Loading vulnerabilities…
CVE-2025-11414
A vulnerability was determined in GNU Binutils 2.45. Affected by this vulnerability is the function get_link_hash_entry of the file bfd/elflink.c of the component Linker. This manipulation causes out-of-bounds read. The attack can only be executed locally. The exploit has been publicly disclosed and may be utilized. Upgrading to version 2.46 addresses this issue. Patch name: aeaaa9af6359c8e394ce9cf24911fec4f4d23703. It is advisable to upgrade the affected component.
This record: live connection— last retrieved: 24 September 2026 at 05:14.
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
A vulnerability was determined in GNU Binutils 2.45. Affected by this vulnerability is the function get_link_hash_entry of the file bfd/elflink.c of the component Linker. This manipulation causes out-of-bounds read. The attack can only be executed locally. The exploit has been publicly disclosed and may be utilized. Upgrading to version 2.46 addresses this issue. Patch name: aeaaa9af6359c8e394ce9cf24911fec4f4d23703. It is advisable to upgrade the affected component.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L
Attack vector
LOCAL
Privileges required
LOW
User interaction
NONE
Confidentiality
None
Integrity
None
Availability
Limited
Probability of exploitation within 30 days
0.2%
Percentile
11e
Source: FIRST.org, updated on 23 September 2026.
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 3.3, EPSS 0.2%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Limited impact on availability; the risk lies mainly with confidentiality or integrity of process data.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Siemens" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 24 September 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.