Loading vulnerabilities…
Loading vulnerabilities…
CVE-2025-13162
Uncontrolled Search Path Element vulnerability in ABB Control Builder A, ABB 800xA for Advant Master. This issue affects Control Builder A: through 1.4/4; 800xA for Advant Master: through 6.0.3-1, through 6.1.1-1, 6.1.1-3, 6.2.0-1.
This record: live connection— last retrieved: 8 November 2026 at 10:21.
Vendor
Published
23 June 2026
Last modified
7 October 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
Uncontrolled Search Path Element vulnerability in ABB Control Builder A, ABB 800xA for Advant Master. This issue affects Control Builder A: through 1.4/4; 800xA for Advant Master: through 6.0.3-1, through 6.1.1-1, 6.1.1-3, 6.2.0-1.
CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:N/I:H/A:N
Attack vector
LOCAL
Privileges required
LOW
User interaction
REQUIRED
Confidentiality
None
Integrity
High
Availability
None
Probability of exploitation within 30 days
0.1%
Percentile
2e
Source: FIRST.org, updated on 7 November 2026.
ABB has investigated the vulnerability and remediated it in the newly released versions. The vulnerability has been resolved in the product versions listed as fixed in the advisory. - Version 6.1.1-2 does not contain this vulnerability and therefore no update is required. The vulnerability was again introduced in 6.1.1-3 when an older ONB version was included in the release media. - Version 6.1.1-4 do not contain this vulnerability but present version 6.1.1-3 by 800xA System Installer and System Configuration Console (SCC). Version 6.1.1-4 is therefore withdrawn. - Version 6.2.0-2 do not contain this vulnerability but present version 6.2.0-1 by 800xA System Installer and System Configuration Console (SCC). Version 6.2.0-2 is therefore withdrawn. ABB recommends that customers apply the update at their earliest convenience. - Control Builder A: It is recommended to update Control Builder A to version 1.4/5 or later. - 800xA for Advant Master: - Versions 6.0.3-1 and earlier, - Versions 6.1.1-1 and earlier, - Versions 6.1.1-2, 6.1.1-3, and 6.1.1-4 should be updated to version 6.1.1-5 or later. - 800xA for Advant Master: - Versions 6.2.0-1 and 6.2.0-2 should be updated to version 6.2.0-3 or later.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 4.4, EPSS 0.1%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Limited impact on availability; the risk lies mainly with confidentiality or integrity of process data.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "ABB" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 8 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.