Loading vulnerabilities…
Loading vulnerabilities…
CVE-2025-22862
An Authentication Bypass Using an Alternate Path or Channel vulnerability [CWE-288] in FortiOS 7.4.0 through 7.4.7, 7.2.0 through 7.2.11, 7.0.6 and above; and FortiProxy 7.6.0 through 7.6.2, 7.4.0 through 7.4.8, 7.2 all versions, 7.0.5 and above may allow an authenticated attacker to elevate their privileges via triggering a malicious Webhook action in the Automation Stitch component.
This record: live connection— last retrieved: 24 September 2026 at 05:10.
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
An Authentication Bypass Using an Alternate Path or Channel vulnerability [CWE-288] in FortiOS 7.4.0 through 7.4.7, 7.2.0 through 7.2.11, 7.0.6 and above; and FortiProxy 7.6.0 through 7.6.2, 7.4.0 through 7.4.8, 7.2 all versions, 7.0.5 and above may allow an authenticated attacker to elevate their privileges via triggering a malicious Webhook action in the Automation Stitch component.
CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Attack vector
LOCAL
Privileges required
HIGH
User interaction
NONE
Confidentiality
High
Integrity
High
Availability
High
Probability of exploitation within 30 days
0.3%
Percentile
17e
Source: FIRST.org, updated on 23 September 2026.
Update Fortigate NGFW to V7.4.9 or later following the secure update recommendation procedure. Contact customer support to receive detailed information
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 6.7, EPSS 0.3%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Siemens" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 24 September 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.