Loading vulnerabilities…
Loading vulnerabilities…
CVE-2025-39683
In the Linux kernel, the following vulnerability has been resolved: tracing: Limit access to parser->buffer when trace_get_user failed When the length of the string written to set_ftrace_filter exceeds FTRACE_BUFF_MAX, the following KASAN alarm will be triggered: BUG: KASAN: slab-out-of-bounds in strsep+0x18c/0x1b0 Read of size 1 at addr ffff0000d00bd5ba by task ash/165 CPU: 1 UID: 0 PID: 165 Comm: ash Not tainted 6.16.0-g6bcdbd62bd56-dirty Hardware name: linux,dummy-virt (DT) Call trace: show_stack+0x34/0x50 (C) dump_stack_lvl+0xa0/0x158 print_address_description.constprop.0+0x88/0x398 print_report+0xb0/0x280 kasan_report+0xa4/0xf0 __asan_report_load1_noabort+0x20/0x30 strsep+0x18c/0x1b0 ftrace_process_regex.isra.0+0x100/0x2d8 ftrace_regex_release+0x484/0x618 __fput+0x364/0xa58 ____fput+0x28/0x40 task_work_run+0x154/0x278 do_notify_resume+0x1f0/0x220 el0_svc+0xec/0xf0 el0t_64_sync_handler+0xa0/0xe8 el0t_64_sync+0x1ac/0x1b0 The reason is that trace_get_user will fail when processing a string longer than FTRACE_BUFF_MAX, but not set the end of parser->buffer to 0. Then an OOB access will be triggered in ftrace_regex_release-> ftrace_process_regex->strsep->strpbrk. We can solve this problem by limiting access to parser->buffer when trace_get_user failed.
This record: live connection— last retrieved: 24 September 2026 at 05:12.
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
In the Linux kernel, the following vulnerability has been resolved: tracing: Limit access to parser->buffer when trace_get_user failed When the length of the string written to set_ftrace_filter exceeds FTRACE_BUFF_MAX, the following KASAN alarm will be triggered: BUG: KASAN: slab-out-of-bounds in strsep+0x18c/0x1b0 Read of size 1 at addr ffff0000d00bd5ba by task ash/165 CPU: 1 UID: 0 PID: 165 Comm: ash Not tainted 6.16.0-g6bcdbd62bd56-dirty Hardware name: linux,dummy-virt (DT) Call trace: show_stack+0x34/0x50 (C) dump_stack_lvl+0xa0/0x158 print_address_description.constprop.0+0x88/0x398 print_report+0xb0/0x280 kasan_report+0xa4/0xf0 __asan_report_load1_noabort+0x20/0x30 strsep+0x18c/0x1b0 ftrace_process_regex.isra.0+0x100/0x2d8 ftrace_regex_release+0x484/0x618 __fput+0x364/0xa58 ____fput+0x28/0x40 task_work_run+0x154/0x278 do_notify_resume+0x1f0/0x220 el0_svc+0xec/0xf0 el0t_64_sync_handler+0xa0/0xe8 el0t_64_sync+0x1ac/0x1b0 The reason is that trace_get_user will fail when processing a string longer than FTRACE_BUFF_MAX, but not set the end of parser->buffer to 0. Then an OOB access will be triggered in ftrace_regex_release-> ftrace_process_regex->strsep->strpbrk. We can solve this problem by limiting access to parser->buffer when trace_get_user failed.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack vector
LOCAL
Privileges required
LOW
User interaction
NONE
Confidentiality
High
Integrity
High
Availability
High
Probability of exploitation within 30 days
0.2%
Percentile
8e
Source: FIRST.org, updated on 23 September 2026.
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 7.8, EPSS 0.2%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Siemens" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 24 September 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.