Loading vulnerabilities…
Loading vulnerabilities…
CVE-2025-39748
In the Linux kernel, the following vulnerability has been resolved: bpf: Forget ranges when refining tnum after JSET Syzbot reported a kernel warning due to a range invariant violation on the following BPF program. 0: call bpf_get_netns_cookie 1: if r0 == 0 goto <exit> 2: if r0 & Oxffffffff goto <exit> The issue is on the path where we fall through both jumps. That path is unreachable at runtime: after insn 1, we know r0 != 0, but with the sign extension on the jset, we would only fallthrough insn 2 if r0 == 0. Unfortunately, is_branch_taken() isn't currently able to figure this out, so the verifier walks all branches. The verifier then refines the register bounds using the second condition and we end up with inconsistent bounds on this unreachable path: 1: if r0 == 0 goto <exit> r0: u64=[0x1, 0xffffffffffffffff] var_off=(0, 0xffffffffffffffff) 2: if r0 & 0xffffffff goto <exit> r0 before reg_bounds_sync: u64=[0x1, 0xffffffffffffffff] var_off=(0, 0) r0 after reg_bounds_sync: u64=[0x1, 0] var_off=(0, 0) Improving the range refinement for JSET to cover all cases is tricky. We also don't expect many users to rely on JSET given LLVM doesn't generate those instructions. So instead of improving the range refinement for JSETs, Eduard suggested we forget the ranges whenever we're narrowing tnums after a JSET. This patch implements that approach.
This record: live connection— last retrieved: 24 September 2026 at 05:11.
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
In the Linux kernel, the following vulnerability has been resolved: bpf: Forget ranges when refining tnum after JSET Syzbot reported a kernel warning due to a range invariant violation on the following BPF program. 0: call bpf_get_netns_cookie 1: if r0 == 0 goto <exit> 2: if r0 & Oxffffffff goto <exit> The issue is on the path where we fall through both jumps. That path is unreachable at runtime: after insn 1, we know r0 != 0, but with the sign extension on the jset, we would only fallthrough insn 2 if r0 == 0. Unfortunately, is_branch_taken() isn't currently able to figure this out, so the verifier walks all branches. The verifier then refines the register bounds using the second condition and we end up with inconsistent bounds on this unreachable path: 1: if r0 == 0 goto <exit> r0: u64=[0x1, 0xffffffffffffffff] var_off=(0, 0xffffffffffffffff) 2: if r0 & 0xffffffff goto <exit> r0 before reg_bounds_sync: u64=[0x1, 0xffffffffffffffff] var_off=(0, 0) r0 after reg_bounds_sync: u64=[0x1, 0] var_off=(0, 0) Improving the range refinement for JSET to cover all cases is tricky. We also don't expect many users to rely on JSET given LLVM doesn't generate those instructions. So instead of improving the range refinement for JSETs, Eduard suggested we forget the ranges whenever we're narrowing tnums after a JSET. This patch implements that approach.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Attack vector
LOCAL
Privileges required
LOW
User interaction
NONE
Confidentiality
None
Integrity
None
Availability
High
Probability of exploitation within 30 days
0.2%
Percentile
7e
Source: FIRST.org, updated on 23 September 2026.
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 5.5, EPSS 0.2%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Siemens" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 24 September 2026.
IEC 62443 mapping