Loading vulnerabilities…
Loading vulnerabilities…
CVE-2025-40149
In the Linux kernel, the following vulnerability has been resolved: tls: Use __sk_dst_get() and dst_dev_rcu() in get_netdev_for_sock(). get_netdev_for_sock() is called during setsockopt(), so not under RCU. Using sk_dst_get(sk)->dev could trigger UAF. Let's use __sk_dst_get() and dst_dev_rcu(). Note that the only ->ndo_sk_get_lower_dev() user is bond_sk_get_lower_dev(), which uses RCU.
This record: live connection— last retrieved: 24 September 2026 at 05:12.
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
In the Linux kernel, the following vulnerability has been resolved: tls: Use __sk_dst_get() and dst_dev_rcu() in get_netdev_for_sock(). get_netdev_for_sock() is called during setsockopt(), so not under RCU. Using sk_dst_get(sk)->dev could trigger UAF. Let's use __sk_dst_get() and dst_dev_rcu(). Note that the only ->ndo_sk_get_lower_dev() user is bond_sk_get_lower_dev(), which uses RCU.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack vector
LOCAL
Privileges required
LOW
User interaction
NONE
Confidentiality
High
Integrity
High
Availability
High
Probability of exploitation within 30 days
0.2%
Percentile
6e
Source: FIRST.org, updated on 23 September 2026.
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 7.8, EPSS 0.2%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Siemens" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 24 September 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.