CVE-2025-41718
A cleartext transmission of sensitive information vulnerability in the affected products allows an unauthorized remote attacker to gain login credentials and access the Web-UI.
This record: live connection— last retrieved: 7 November 2026 at 14:22.
Vendor
Published
14 October 2025
Last modified
18 October 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
A cleartext transmission of sensitive information vulnerability in the affected products allows an unauthorized remote attacker to gain login credentials and access the Web-UI.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Confidentiality
High
Integrity
None
Availability
None
Probability of exploitation within 30 days
0.2%
Percentile
16e
Source: FIRST.org, updated on 6 November 2026.
Murrelektronik recommends: * Deactivating the Webserver will prevent any data from being sent unencrypted. More information on how to disable the webserver can be found in the manual. * Deactivating all unused network ports in the unit will prevent data sniffing. * Segmenting the network strictly helps to minimize unauthorized access to network traffic. If the webserver must stay activated, this is recommended to reduce the security breaches impact. * Advise users of the system to not use personal data or standard passwords for the webserver accounts. This helps to prevent personal data leakage.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 7.5, EPSS 0.2%, industrial relevance 40/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Limited impact on availability; the risk lies mainly with confidentiality or integrity of process data.
No strong energy-sector-specific signals recognised; general OT/ICS relevance.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.