Loading vulnerabilities…
Loading vulnerabilities…
CVE-2025-41726
A low privileged remote attacker can execute arbitrary code by sending specially crafted calls to the web service of the Device Manager or locally via an API and can cause integer overflows which then may lead to arbitrary code execution within privileged processes.
This record: live connection— last retrieved: 7 November 2026 at 14:22.
Vendor
Products
Beckhoff.Device.Manager.XAR, IPC Diagnosticssoftware for Windows, MDP.dll library for Windows CE 6.0 and Embedded Compact 7, MDP software package for TwinCAT/BSD, MDP for Beckhoff RT Linux(R)
up to version vers:semver/<2.5.3
Published
27 January 2026
Last modified
17 June 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
A low privileged remote attacker can execute arbitrary code by sending specially crafted calls to the web service of the Device Manager or locally via an API and can cause integer overflows which then may lead to arbitrary code execution within privileged processes.
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Attack vector
NETWORK
Privileges required
LOW
User interaction
NONE
Confidentiality
High
Integrity
High
Availability
High
Probability of exploitation within 30 days
0.5%
Percentile
42e
Source: FIRST.org, updated on 6 November 2026.
Please update to a recent version of the affected components or update the complete operating system image. Operating system images are available on request from Beckhoff's service (service@beckhoff.com). The setup / installer for Windows 10 and 11 are available on request from Beckhoff's service also.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 8.8, EPSS 0.5%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Beckhoff" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.