Loading vulnerabilities…
Loading vulnerabilities…
CVE-2025-46818
Redis is an open source, in-memory database that persists on disk. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to manipulate different LUA objects and potentially run their own code in the context of another user. The problem exists in all versions of Redis with LUA scripting. This issue is fixed in version 8.2.2. A workaround to mitigate the problem without patching the redis-server executable is to prevent users from executing LUA scripts. This can be done using ACL to block a script by restricting both the EVAL and FUNCTION command families.
This record: live connection— last retrieved: 7 November 2026 at 14:22.
Vendor
Published
3 October 2025
Last modified
19 October 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
Redis is an open source, in-memory database that persists on disk. Versions 8.2.1 and below allow an authenticated user to use a specially crafted Lua script to manipulate different LUA objects and potentially run their own code in the context of another user. The problem exists in all versions of Redis with LUA scripting. This issue is fixed in version 8.2.2. A workaround to mitigate the problem without patching the redis-server executable is to prevent users from executing LUA scripts. This can be done using ACL to block a script by restricting both the EVAL and FUNCTION command families.
CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:H/I:H/A:N
Attack vector
LOCAL
Privileges required
LOW
User interaction
REQUIRED
Confidentiality
High
Integrity
High
Availability
None
Probability of exploitation within 30 days
0.7%
Percentile
55e
Source: FIRST.org, updated on 6 November 2026.
Patch ProLeiT-2025-001 includes a fix to reduce the risk of exploit: • Install the patch to disable the eval commands in Redis on: o Application Server o VisuHub o Engineering Workstations o Workstation with emergency mode functionality • The patch ProLeiT-2025-001 is available via ProLeiT Support: https://www.proleit.com/support/ • Force usage of secure Redis configuration templates in system settings as documented in the patch manual. • Restart all patched Servers and Workstations
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 6.0, EPSS 0.7%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Limited impact on availability; the risk lies mainly with confidentiality or integrity of process data.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Schneider Electric" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.