Loading vulnerabilities…
Loading vulnerabilities…
CVE-2025-68615
net-snmp is a SNMP application library, tools and daemon. Prior to versions 5.9.5 and 5.10.pre2, a specially crafted packet to an net-snmp snmptrapd daemon can cause a buffer overflow and the daemon to crash. This issue has been patched in versions 5.9.5 and 5.10.pre2.
This record: live connection— last retrieved: 7 November 2026 at 14:22.
Vendor
Products
Managed Ethernet Switch TBEN-LL-SE-M2, Managed Ethernet Switch TBEN-L4-SE-M2, Managed Ethernet Switch TBEN-L5-SE-M2
up to version vers:semver/<2.1.2.0
Published
23 December 2025
Last modified
20 October 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
net-snmp is a SNMP application library, tools and daemon. Prior to versions 5.9.5 and 5.10.pre2, a specially crafted packet to an net-snmp snmptrapd daemon can cause a buffer overflow and the daemon to crash. This issue has been patched in versions 5.9.5 and 5.10.pre2.
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Confidentiality
High
Integrity
High
Availability
High
Probability of exploitation within 30 days
42.4%
Percentile
99e
Source: FIRST.org, updated on 6 November 2026.
Turck recommends to update to the latest 2.1.2.0 Firmware Release which fixes these vulnerabilities.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 9.8, EPSS 42.4%, industrial relevance 65/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Productbeschrijving komt overeen met de categorie "industrial-switch", een typisch OT/ICS-componenttype. Description mentions industrial protocol: snmp.
Recommended defensive measures
Industrial relevance score
Automatically classified as industrially relevant based on CISA/NVD signals (see reasons).
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.