Loading vulnerabilities…
Loading vulnerabilities…
CVE-2025-68820
In the Linux kernel, the following vulnerability has been resolved: ext4: xattr: fix null pointer deref in ext4_raw_inode() If ext4_get_inode_loc() fails (e.g. if it returns -EFSCORRUPTED), iloc.bh will remain set to NULL. Since ext4_xattr_inode_dec_ref_all() lacks error checking, this will lead to a null pointer dereference in ext4_raw_inode(), called right after ext4_get_inode_loc(). Found by Linux Verification Center (linuxtesting.org) with SVACE.
This record: live connection— last retrieved: 24 September 2026 at 05:13.
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
In the Linux kernel, the following vulnerability has been resolved: ext4: xattr: fix null pointer deref in ext4_raw_inode() If ext4_get_inode_loc() fails (e.g. if it returns -EFSCORRUPTED), iloc.bh will remain set to NULL. Since ext4_xattr_inode_dec_ref_all() lacks error checking, this will lead to a null pointer dereference in ext4_raw_inode(), called right after ext4_get_inode_loc(). Found by Linux Verification Center (linuxtesting.org) with SVACE.
CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Confidentiality
None
Integrity
None
Availability
None
Probability of exploitation within 30 days
0.2%
Percentile
11e
Source: FIRST.org, updated on 23 September 2026.
Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 5.5, EPSS 0.2%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Limited impact on availability; the risk lies mainly with confidentiality or integrity of process data.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Siemens" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 24 September 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.