Loading vulnerabilities…
Loading vulnerabilities…
CVE-2026-10765
RTU500 contains a denial-of-service vulnerability in its IEC 61850 MMS server implementation. A malicious user with access to the IEC 61850 interface can trigger improper handling of asynchronous control operations involving special response and timing criteria. This may result in access to invalid memory structures, leading to a software exception, loss of IEC 61850 communications, or device reboot.
This record: live connection— last retrieved: 25 November 2026 at 00:04.
Vendor
Product
Published
24 November 2026
Last modified
24 November 2026
Assessment
Medium55/100Industrial relevance
Medium50/100Confidence
LowPriority 55/100: relevant, but less urgent than the highest-priority vulnerabilities.
Based on CVSS 5.9, no EPSS score available, industrial relevance 50/100.
No confirmed exploitation known: not on the CISA KEV list.
No EPSS score available yet.
Sources
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
RTU500 contains a denial-of-service vulnerability in its IEC 61850 MMS server implementation. A malicious user with access to the IEC 61850 interface can trigger improper handling of asynchronous control operations involving special response and timing criteria. This may result in access to invalid memory structures, leading to a software exception, loss of IEC 61850 communications, or device reboot.
CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H
Attack vector
NETWORK
Privileges required
NONE
User interaction
NONE
Confidentiality
None
Integrity
None
Availability
High
No EPSS score available at the time of retrieval (e.g. for a very recent CVE).
No official patch information available at the time of retrieval; consult the official source.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 5.9, no EPSS score available, industrial relevance 50/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
No strong energy-sector-specific signals recognised; general OT/ICS relevance.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 25 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.