CVE-2026-110935
The PFI plugin framework deployment routine does not validate path components when extracting archive entries to the local plugin repository. Archive entries containing relative path segments such as '..' are not rejected, allowing an unauthenticated local attacker to write files outside the plugin repository to arbitrary locations accessible with the current user's permissions which could result in full system compromise.
This record: live connection— last retrieved: 7 November 2026 at 00:32.
Vendor
Published
4 November 2026
Last modified
4 November 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
The PFI plugin framework deployment routine does not validate path components when extracting archive entries to the local plugin repository. Archive entries containing relative path segments such as '..' are not rejected, allowing an unauthenticated local attacker to write files outside the plugin repository to arbitrary locations accessible with the current user's permissions which could result in full system compromise.
CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Attack vector
LOCAL
Privileges required
NONE
User interaction
NONE
Confidentiality
High
Integrity
High
Availability
High
Probability of exploitation within 30 days
0.2%
Percentile
9e
Source: FIRST.org, updated on 6 November 2026.
Phoenix Contact strongly recommends to upgrade to PLCnext Engineer 2026.6 which fixes these vulnerabilities.
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 8.4, EPSS 0.2%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Possible loss of visibility of or control over the process upon successful exploitation.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Phoenix Contact" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 7 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.