Loading vulnerabilities…
Loading vulnerabilities…
CVE-2026-119055
CWE- 416: Use After Free vulnerability exists that could cause arbitrary code execution when a local attacker could trick the end user to open a specially crafted malicious SSD file.
This record: live connection— last retrieved: 20 November 2026 at 19:46.
Vendor
Published
11 November 2026
Last modified
16 November 2026
Taken directly from NVD, CISA or the vendor — sometimes in English, unchanged from the source.
CWE- 416: Use After Free vulnerability exists that could cause arbitrary code execution when a local attacker could trick the end user to open a specially crafted malicious SSD file.
CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:A/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
Attack vector
LOCAL
Privileges required
NONE
User interaction
REQUIRED
Confidentiality
Limited
Integrity
Limited
Availability
Limited
Probability of exploitation within 30 days
0.2%
Percentile
5e
Source: FIRST.org, updated on 20 November 2026.
Versions FR V2.9.12.0101, ESP V2.9.5.0000, PT V2.9.7.0000, BEL(FR) V2.9.8.0000, BEL(EN) V2.9.3.0000, INT(EN) V2.9.4.0000, INT(FR)V2.9.6.0000, NL V2.9.6.0000 of EcoStruxure™ Power Build Rapsody software includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-country-selector/?pageType=product-range&sourceId=2309
Our own interpretation and context for the source data above.
IACS Radar assessment
Our own interpretation and context for this vulnerability — not an official source.
IACS Radar priority score
Based on CVSS 4.6, EPSS 0.2%, industrial relevance 55/100.
Combines CVSS, EPSS, KEV status, industrial relevance and exposure relevance — a complement to, not a replacement for, the individual scores below and above.
Conditions for exploitation
Operational impact & energy relevance
Limited impact on availability; the risk lies mainly with confidentiality or integrity of process data.
Assessed as relevant to the energy sector based on: Vermeld in een officiële CISA ICS Advisory, wat directe relevantie voor industriële besturingssystemen bevestigt. Vendor "Schneider Electric" is a known supplier of equipment for the energy sector.
Recommended defensive measures
Industrial relevance score
Classification is provisional; manual verification by an OT security analyst is recommended.
Classified by IACS Radar-analysepijplijn (geautomatiseerd) on 20 November 2026.
IEC 62443 mapping
Automatic IACS Radar assessment based on the reported CWE weakness classification; not an official certification statement.